Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • Labelling kit  (1)
  • Third ventricle  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 33 (1991), S. 354-356 
    ISSN: 1432-1920
    Keywords: Meningioma ; Third ventricle ; Magnetic resonance imaging ; Computed tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Meningiomas of the third ventricle are rare intracranial neoplasms. We reported such a case in a 42 years old man without clinical evidence of increased intracranial pressure. Computed tomography (CT) and magnetic resonance imaging (MRI) demonstrated the tumour sitting in the superior and anterior part of the third ventricle, bulging into the lateral ventricles. CT was more effective than MRI in the demonstration of calcifications whereas MRI proved to be superior in delineation of the tumour and its relation with surrounding structures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Technetium-99m labelled human serum albumin ; Labelling kit ; Ventriculography ; Blood pool agent
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%–70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...