Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 3 (1985), S. 350-359 
    ISSN: 0736-0266
    Keywords: Human locomotion ; Repeatability ; Phasic muscle activity ; Surface electrodes ; Intramuscular wire electrodes ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Repeatability is an important consideration for gait analysis data that are being used as an adjunct to clinical decision making. An index of repeatability of wave forms over a number of identical cycles. The purpose of this study was to use the variance ratio to assess the repeatability of phasic muscle activity recorded with surface and bipolar imtramuscular wire electrodes during gait on 10 normal subjects. Variance ratios were calculated using rectified and smoothed elctromyographic data recorded simultaneously from the two types of electrodes. Three measures of repeatability (reproducibility, reliability, and constancy - defined as the cycle-to-cycle, run-to-run, and day-to-day repeatability of phasic muscle activity) were used to compare the performance of the two electrode techniques. Results show that the reproducibility and reliability were better for surface elctrodes than for intramuscular wire electrodes, and constancy was good for sufrace elctrodes and poor for intramuscular wire electrodes. Repeatability improved with increasing smoothing window lengths but was better for surface electrodes than wire electrodes, irrespective of the smoothing window. This study indicates that surface electrode data represent a more consistent measure of activity of superficial muscles, if comparisons are to be made between gait data from different test days.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 3 (1985), S. 508-513 
    ISSN: 0736-0266
    Keywords: Electrical stimulation ; Osteogenesis ; Internal fixation ; Piezoelectric ; Ultrasonics ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Prototype testing has been accomplished on a piezoelectric, internal fixation plate. This device combines a piezoelectric material with an internal fixation device as an integrated structure that provides mechanical stability, together with self-generated electrical stimulation, for treating fractures and nonunion. In bench and animal tests we have demonstrated that cyclical loading can cause a device of this type to generate electrical charge while attached to bone. After rectification, direct currents within the range known to stimulate osteogenesis can be produced by weighed-bearing loads. Furthermore, electrical output of the implants can be increased by externally applied ultrasonic energy. These twin developments and significantly to the potential armamentarium of devices to enhance bone healing.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 7 (1989), S. 849-860 
    ISSN: 0736-0266
    Keywords: Gait analysis ; Repeatability ; Coefficient of multiple correlation ; Kinematics ; Kinetics ; Electromyography ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The repeatability of gait variables is an important consideration in the clinical use of results of quantitative gait analysis. Statistical measures were used to evaluate repeatability of kinematic, kinetic, and electromyographic data waveforms and spatiotemporal parameters of 40 normal subjects. Subjects were evaluated three times on each test day and on three different test days while walking at their preferred or natural speed. Intrasubject repeatability was excellent for kinematic data in the sagittal plane both within a test day as well as between test days. For joint angle motion in the frontal and transverse planes, the repeatability was good within a test day and poor between test days. Poor between-day repeatability of joint angle motion in the frontal and transverse planes was noted to be partly due to variabilities in the alignment of markers. Vertical reaction and fore-aft shear forces were more repeatable than the mediolateral shear force. Sagittal plane joint moments were more repeatable than frontal or transverse plane moments. For electromyographic data, repeatability within a day was slightly better than between test days. In general, the results demonstrate that with the subjects walking at their natural or preferred spped, the gait variables are quite repeatable. These observations suggest that it may be reasonable to base significant clinical decisions on the results of a single gait evaluation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...