Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 1 (1983), S. 244-250 
    ISSN: 0736-0266
    Keywords: Fracture behavior ; Axial-torsional loading ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: This study was undertaken to determine the effect of loading rate on bone failure under singular and combined loading states. Using the entire loading range of an Instron Materials Testing Machine, 190 pairs of canine radii were tested. One bone of each pair was subjected to either torsional or a combination of axial and torsional loads, and compared with a control specimen. Compressive loads of 4.6 and 11.5 N were utilized. Torque to failure and energy data versus loading rate were plotted. As loading rate increased, the torque and energy values were found to increase, reach a peak, and then decline at higher rates. Fractures produced under the combined state of loading are representative of those clinically found in human trauma situations.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource