    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 31-38 
    ISSN: 0935-6304
    Keywords: Efficiency, erosion of ; Non-uniform chromatography ; Linear chromatography ; Plate height, uniform ; Solute velocity ; Capacity ratio, variation ; SFC pressure drop ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In linear chromatography (i.e. chromatography performed in the absence of sample overloading), when the plate height of a column is roughly uniform along its length, variations in the velocities of solutes are the only possible causes of erosion of efficiency. The sources of these variations (variations in capacity ratio and in the density of the mobile phase, etc.) play no direct role in the erosion of efficiency except through their effect on solute velocities. In other words, what eventually causes the erosion of efficiency is merely variation in the time required for solutes to traverse equally small segments of a column. Significant erosion can only arise from abrupt and deep deceleration of solutes in one or several relatively small segments of a column.If erosion of efficiency caused by pressure gradients in linear SFC is to be large, the depth and the sharpness of the deceleration of a solute must go beyond that hitherto confirmed experimentally. Many relevant examples are analyzed graphically.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 235-242 
    ISSN: 0935-6304
    Keywords: TCD ; Sensitivity ; Concentration-sensitive detector ; TCD cell volume ; Capillary column diameter ; Analysis speed ; Statistical errors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The concentration sensitivity of a thermal conductivity detector (TCD) depends, among other factors, on the amount of sample mixture in the detector's sensing cell. Since the cell volume has to be appropriately matched with column diameter, it makes the concentration sensitivity of a TCD dependent on column diameter and, therefore, on the speed of gas chromatography. Through reduction of column diameter, higher speed tends to lead to a reduction in the concentration sensitivity of the cell. The factor which the most directly affects the concentration sensitivity of a TCD cell is the heat power conducted through the cell. The higher the power, the greater the sensitivity. The limit of detection of a TCD depends on the concentration-sensitivity of its cell and on the level of statistical errors in the measurement. The errors increase with increasing analysis speed. As the column diameter is reduced, the errors cause additional worsening (on top of the decrease in concentration sensitivity) of the detection limit, dynamic range, and other performance characteristics of the TCD.
    Additional Material: 5 Ill.