Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2013
    Keywords: Acridine red ; Dextrans ; Fluorescence ; Intravital microscopy ; Microcirculation ; Platelets ; Rheology ; Rabbit mesentery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Dextrans bind to the surface of platelets, red blood cells and endothelium. We investigated whether a low doses (30 mg/kg IV) of 40-kDa (Dx40), neutral, 500-kDa (Dx500) or sulphated, 500-kDa (Dx500S) dextrans influence platelet distribution in rabbit mesenteric arterioles and venules (diameter 17–33 μm). Intravital fluorescence videomicroscopy was used to visualize platelets labelled in vivo with acridine red. Their concentration distribution determined within a thin optical section about the median vessel plane was expressed relative to the mean concentration in that vessel. In arterioles, Dx500 and Dx500S increased the relative platelet concentration in the centre [radial position (R): 0.0–0.47 R] from 0.60 to 1.07 (P〈0.001) and 1.20 (P〈0.003), and reduced it near the wall (0.8–0.9 R) from 1.59 to 0.93 (P〈0.02) and 0.95 (P〈0.03) respectively. In venules a similar, but non-significant, effect was observed. Dx40 did not change platelet distribution in arterioles, but decreased their concentration in venules in the centre from 1.08 to 0.71 (P〈0.03) and increased it at the wall from 0.89 to 1.27 (P〈0.04). The deformability of red blood cells was unchanged, but their aggregation tendency increased approximately twofold after Dx500 and Dx500S injection, while Dx40 had no influence. Leucocyte margination in venules did not affect platelet distribution. Dextran injection did not change microvascular flow velocity or plasma viscosity, suggesting that the observed changes in arteriolar platelet distribution were caused by binding of dextran to the surface of platelets and/or red blood cells.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-9686
    Keywords: Dual-slit method ; Spatial correlation ; Spatial filtering ; Temporal correlation ; Velocity ; Microcirculation ; Red blood cell
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Several methods to measure red blood cell velocity in microvessels by electronic means are discussed. Signals are generated by the red blood cells present in the microscopic image of the microvessels. These signals can be converted to obtain an output signal proportional to the actual red blood cell velocity. The method of spatial filtering by interlacing gratings is discussed in terms of a filter with an input signal. Adaptation of optical factors that might improve the velocity measurement is obtained by a mathematical analysis. Different methods of correlation are presented. The temporal correlation (dual slit and video window) and spatial correlation methods are discussed in relation to factors influencing the quality of the correlogram, the peak of which is proportional to red blood cell velocity. The conversion of red blood cell velocity to volume flow is put in perspective.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...