Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Molecular genetics and genomics 253 (1997), S. 439-447 
    ISSN: 1617-4623
    Keywords: Key words Saccharomyces cerevisiae ; Polyubiquitin gene ; Catabolite derepression ; Oxidative stress survival
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract  Carbon and nitrogen regulation of UBI4, the stress-inducible polyubiquitin gene of Saccharomyces cerevisiae, was investigated using a UBI4 promoter-LacZ fusion gene (UBI4-LacZ). Expression of this gene in cells grown on different media indicated that the UBI4 promoter is more active during growth on respiratory than on fermentable carbon sources but is not subject to appreciable control by nitrogen catabolite repression. UBI4-LacZ expression was virtually identical in cells having constitutively high (ras2, sra1-13) or constitutively low (ras2) levels of cyclic AMP-dependent protein kinase activity, indicating that this kinase does not exert a major influence on UBI4 expression. Catabolite derepression control of the UBI4 promoter was confirmed by measurements of UBI4-LacZ expression in hap mutant and wild-type strains before and after transfer from glucose to lactate. Mutagenesis of the perfect consensus for HAP2/3/4 complex binding at position −542 resulted in considerable reduction of UBI4 promoter derepression with respiratory adaptation in HAP wild-type cells and abolished the reduced UBI4-LacZ derepression normally seen when aerobic cultures of the hap1 mutant are transferred from glucose to lactate. This HAP2/3/4 binding site is therefore a major element contributing to catabolite derepression of the UBI4 promoter, although data obtained with hap1 mutant cells indicated that HAP1 also contributes to this derepression. The HAP2/3/4 and HAP1 systems are normally found to activate genes for mitochondrial (respiratory) functions. Their involvement in mediating higher activity of the UBI4 promoter during respiratory growth may reflect the contribution of UBI4 expression to tolerance of oxidative stress.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2614
    Keywords: Monitoring ; neuromuscular blockade ; peripheral nerve stimulation ; supramaximal stimulation ; Equipment ; peripheral nerve stimulators ; Measurement techniques ; neuromuscular blockade ; electrodes ; interelectrode impedance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract Questions have been raised concerning the reliability of surface electrodes in achieving supramaximal stimulation during the monitoring of neuromuscular blockade; needle electrodes are considered reliable in this respect. This study compares interelectrode impedances of needle and surface electrodes during neuromuscular blockade monitoring and suggests those characteristics of the stimulation pulse that can ensure reliable supramaximal stimulation with either type of electrode. Interelectrode voltage and current for surface and needle electrodes were measured by using 1.0-ms pulses at low, medium, and high stimulation levels on 22 surgical patients during anesthesia. Data were collected immediately after electrode application, and again at 10 minutes after application. Stimulation with surface electrodes produced an initial, transient surge of current, followed by a lower steady-state value. At high stimulation levels, the peak transient current was 87% higher than the steady-state current. Needle electrodes produced a constant high-current response. At high stimulation levels the transient impedance of the surface electrode and the impedance of the needle electrode were essentially equal (0.7 kΩ and 0.75 kΩ, respectively). The transient impedance was significantly lower (P〈0.001) and was associated with less interpatient variation (P〈0.001) and less sensitivity to the duration of electrode application than was the steady-state impedance of the surface electrode. These data suggest that high-current pulses with widths of less than 0.2 ms could provide reliable supramaximal stimulation with either type of electrode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...