Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1573-2568
    Schlagwort(e): gastric recordings ; data acquisition ; digital signal processing ; aliasing ; filtering ; Fourier transform ; Nyquist theorem
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Despite the fact that digital techniques for data acquisition and processing were widely used in electrogastrographic (EGG) research during the last decade, inappropriate signal conditioning and digitization are still potential pitfalls threatening the reliability of the experiments. The aim of this paper was to review: (1) the importance of the antialiasing low-pass filtering for reducing recording artifacts and interferences, (2) the advantages brought by the proper choice of filter cutoff frequency and the slope for the decrement of the minimal required sampling frequency, (3) the impact of incorrectly selected sampling frequency on data interpretations, with particular attention to the percent distribution ranges, and (4) the “leakage effect” related to the finite number of samples processed simultaneously in frequency domain representation of the recordings. A model of electrogastrographic (EGG) recording was mixed with a model of electrocardiographic (ECG) artifact. The resulting finite-duration signal was low-pass filtered and then digitized with a sampling frequency of 1 Hz. The cutoff frequency of the first-order low-pass filter was altered from 0.5 to 0.1 Hz. Amplitude frequency spectra of the digitized recordings were investigated. An example with a real human electrogastrogram in which an ECG artifact was present confirmed the simulation results. When a first-order anti-aliasing filter is utilized at least a fivefold difference between the filter cutoff frequency and the sampling frequency is recommended for compliance with the Nyquist theorem of digitization. Leakage effects associated with the finite-time duration of the recordings and the use of the discrete Fourier transform should be considered when frequency domain analysis is performed. Misinterpretation of the “bradygastric” and “tachygastric” ranges in the percent distribution of EGG frequency components is possible if inappropriate signal conditioning and digitization are employed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...