Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Occupational Health and Environmental Toxicology  (2)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 17 (1996), S. 1-2 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 97-105 
    ISSN: 0197-8462
    Keywords: atrioventricular block ; heat coagulation ; reversible and irreversible block ; catheter antenna ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The use of microwave energy for ablation of the atrioventricular (AV) junction was examined in open-chest dogs. Using a specially designed microwave catheter and a 2450 MHz generator, microwave energy was delivered to the AV junction according to one of two protocols. In protocol 1, increasing amounts of energy were delivered until irreversible AV block occurred. In protocol 2, only two applications of energy were used, one at low energy and the other at an energy found to be high enough to cause irreversible AV block. Each dog received between one and six applications of microwave energy. The amount of energy delivered per application ranged from 25.6 to 311.4 J. No AV block was seen at 59.4 ± 28.3 J. Reversible AV block was seen with an energy of 120.6 ± 58 J. Irreversible AV block was seen at 188.1 ± 75.9 J. Irreversible AV block could be achieved in each animal. There was no difference in the energy required to cause irreversible AV block between the two protocols. The tissue temperature measured near the tip of the microwave catheter was correlated with both the amount of energy delivered and the extent of AV block caused. Histologic examination demonstrated coagulation necrosis of the conduction system. Microwave energy is a feasible alternative energy source for myocardial ablation. Since tissue damage is due exclusively to heating and the resulting rise in temperature can be measured, microwave energy may have advantages over currently existing energy sources in terms of both titrating delivered energy and monitoring the extent of tissue destruction. © 1995 Wiley-Liss, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...