Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology  (4)
  • Electron microscopy  (2)
  • 1
    ISSN: 1432-0878
    Keywords: Neurohypophysis ; Neurosecretion ; Neurophysin ; Neurohypophysia hormones ; Electron microscopy ; Autoradiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Electron-microscope autoradiographs have been prepared from the neural lobes of the pituitary glands of rats which had received intracisternal injections of [35S] cysteine at various times before gland removal. The rate of appearance and disappearance of autoradiographically demonstrable radioactivity in the neural lobe closely paralleled that previously determined, biochemically, for radioactive hormones and neurophysins. Radioactivity was appreciably associated with the undilated parts of neurosecretory axons only during the first few hours after injection of the label. The axonal dilations were subdivided into those in which small vesicles could be seen (“endings”) and those in which no small vesicles could be seen (“swellings”). Radioactivity appeared first in “endings” and then in progressively larger and larger profiles of “swellings”. It appeared that newly arrived granules were found close to the limiting membrane of the nerve swelling and that as time progressed they moved deeper and deeper into the swelling. On the basis of the results, suggestions were made for an anatomical explanation of the readily-releasable pool of hormone which has been demonstrated pharmacologically.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0878
    Keywords: Gastrin cells ; Electron microscopy ; Fixation ; Granule maturation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The ultrastructural appearance of gastrin cell (G cell) granules was studied after different fixation procedures. When the pH of prefixation was varied there was greater preservation of the electron density of granule cores after acidic (pH 5.0 and 6.0) than after neutral or alkaline (pH 7.0 and 8.0) prefixation. Increasing duration of prefixation at pH 7.3 resulted in progressive loss of electron density of the granule core with swelling and occasional rupture of the limiting membrane. In tissues where most granules had been rendered electron lucent by fixation, those granules remaining dense cored were preferentially located close to the Golgi zone. These findings indicate that the electron density of G cell granules is profoundly affected by conditions of fixation, and that immature granules are more resistant to loss of core density than mature granules. They also suggest that the gastrin granule in vivo, like other polypeptide granules, may have a “solid”, osmotically inactive core.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 341-347 
    ISSN: 0197-8462
    Keywords: immunology ; mice ; 60-Hz electric fields ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: We evaluated humoral and cellular functions of the immune system of Swiss-Webster mice exposed to 60-Hz electric fields at 100 kV/m. No significant differences were observed in primary antibody response to keyhole limpet hemocyanin (precipitating antibody levels) between exposed (30 or 60 days) and control mice, nor were there significant changes in mitogen-stimulation response of spleen cells from mice similarly exposed for 90 or 150 days when compared to sham-exposed animals.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 383-396 
    ISSN: 0197-8462
    Keywords: hematology ; immunology ; mice ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Mice were exposed in the far field in an anechoic chamber to 2,880-MHz pulsed microwaves 3 to 7.5 h daily, 5 days/week for 60 to 360 h. Three experiments were performed at average power densities of 5 mW/cm2 and six at 10 mW/cm2, corresponding to averaged specific absorption rates (SARs) of 2.25 and 4.50 mW/g, respectively. Each experiment consisted of eight mice, with a concurrently sham-exposed group of eight. In two of three studies at 5 mW/cm2, there was a significant increase in bone marrow cellularity in the microwave-exposed groups compared to the sham-exposed groups. Significant differences were occasionally seen in erythrocyte, leukocyte, and platelet values from microwaveexposed groups, but were not consistently observed. In one of six groups exposed at 10 mW/cm2, mean bone marrow cellularity was reduced significantly in the microwaveexposed mice; in another group, the lymphocyte count was increased. In only one exposure (10 mW/cm2 for 360 h) was any significant effect noted on serum proteins: a reduction to 5.1 ± 0.3 g/dl in the exposed versus 5.6 ± 0.4 g/dl in the sham-exposed mice. This was due to a decrease in alpha and beta globulins, with no effect on albumin or gamma globulin concentrations. No effect on bone marrow granulocyte/macrophage colony-forming units (CFU) was revealed following exposure of mice to pulsed microwaves at 5 mW/cm2. In one of four exposures at 10 mW/cm2, there was a significant increase in CFU-agar colonies. No significant effects of exposures at 10 mW/cm2 were observed on in vivo and in vitro assays of cell-mediated immune functions. No exposure-related histopathologic lesions were found from examination of several tissues and organs. Results of these series of exposures of mice at SARs of 2.25 and 4.50 mW/g indicated no consistent effects on the hematologic, immunologic, or histopathologic variables examined.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0197-8462
    Keywords: alkaline elution ; human lymphocytes ; DNA damage ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: DNA damage was induced in isolated human peripheral lymphocytes by exposure at 5 Gy to 60Co radiation. Cells were permitted to repair the DNA damage while exposed to 60-Hz fields or while sham-exposed. Exposed cells were subjected to magnetic (B) or electric (E) fields, alone or in combination, throughout their allotted repair time. Repair was stopped at specific times, and the cells were immediately lysed and then analyzed for the presence of DNA single-strand breaks (SSB) by the alkaline-elution technique. Fifty to 75 percent of the induced SSB were repaired 20 min after exposure, and most of the remaining damage was repaired after 180 min. Cells were exposed to a 60-Hz ac B field of 1 mT; an E field of 1 or 20 V/m; or combined E and B fields of 0.2 V/m and 0.05 mT, 6 V/m and 0.6 mT, or 20 V/m and 1 mT. None of the exposures was observed to affect significantly the repair of DNA SSB.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 12 (1991), S. 21-25 
    ISSN: 0197-8462
    Keywords: field-related movement ; electromagnetic field ; geomagnetic field ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effect of a 16-Hz electromagnetic field on the mobility of the diatom Amphora coffeaformis was examined on agar plates that contained no added calcium and also on agar plates containing 0.25 or 2.5 mM exogenous Ca2+. Exposure conditions consisted of an ac field of 16 Hz with an amplitude of 20.9 μT parallel to the horizontal component of the dc field (BH = 20.9 μT, where Bv = 0). To assess results, the percentage of diatoms that moved a distance greater than their body length was determined. We observed the field-associated increase in diatom motion at 0.25 mM Ca++, which was previously reported in the literature. Although the magnitude of the effect at 16 Hz was significant, the percentage of cells that moved was not sufficiently reproducible to allow examination for frequency dependence.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...