Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Membrane-extraction disks ; On-line trace enrichment ; Polar pollutants ; Surface water
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An on-line trace-enrichment system, using a bifunctional membrane extraction-disk cartridge, has been combined with a column liquid chromatography separation for the simultaneous determination of basic, neutral and acidic pollutants in surface water. The enrichment device consisted of a specially constructed holder containing both C-18 and cation-exchange disks. The holder can contain up to 25 disks of 0.5 mm thickness and 4.6 mm diameter. Before trace enrichment of 20 ml of surface water (pH 3.0), calcium ions were removed from the sample by means of an oxalic acid precipitation. Desorption of the cartridge was at elevated temperature using reversed-phase gradient elution; detection was performed with a diode-array UV absorbance detector. The detection limits for the test compounds in surface water are typically 0.5–2 μg/l; the calibration graphs are linear from the lower limit of determination up to 50 μg/l.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Narrow-bore column liquid chromatography ; Post-column derivatization ; Solid-phase reactors ; Catalytic hydrolysis ; On-line trace enrichment ; Immobilized enzyme
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of solid-phase reactors for post-column derivatization in narrow-bore HPLC (1.0mm i.d. analytical columns) is evaluated. Two systems are described, viz. for the determination of N-methylcarbamate pesticides and for that of urea and ammonia. The solid-phase reactor is packed with a strong anion exchange resin and urease immobilized on silica, respectively, to effect the catalytic hydrolysis of the solutes eluting from the analytical column. In both systems, the hydrolysis product is reacted with o-phthalaldehyde followed by fluorescence monitoring. Analytical data are presented and band broadening from various parts of the reaction detector system is discussed. An on-line trace enrichment procedure via a micro precolumn is descried for the trace level determination of N-methylcaramates in surface water samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polar pollutants in water ; On-line trace enrichment ; Humic substances
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A practical liquid chromatographic early-warning system for polar pollutants in water ought to have detection limits at a level below a microgram per litre. Using ultraviolet absorbance detection this normally necessitates trace enrichment of the samples. In this study ten different sorbents have been tested with respect to their enrichment capacity. The hydrophobic polymeric PLRP-S material, in combination with a C-18 modified analytical column, proved to be the best choice. The influence of humic substances, present in surface water, was also studied. Lowering of the sample pH, resulted in a significant increase in the interferences due to the humic substances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...