Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0827
    Keywords: Menopause ; Bone loss ; Osteoporosis ; Bone densitometry ; Biochemical markers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The main objective of this study was to describe longitudinal patterns of spinal bone loss in normal women who undergo a natural menopause. The second objective was to determine if a proportion of women suffer excessively rapid postmenopausal bone loss from the spine. If this was the case it was the aim to devise a means of predicting the women at excess risk; but if all women lost bone at similar rates, the aim was to document changing loss rates over the first 5–8 postmenopausal years. Responding women in six suburban general practices recalled for cervical smears who had their last menstrual period 9–36 months previously were invited to participate in a longitudinal study of bone loss and the biochemical markers plasma osteocalcin and urinary hydroxyproline. Sixty-four subjects agreed to participate, a response rate of 80%. In the ensuing 5 years, six received hormone replacement therapy and are not reported on. The main outcome measures were rates of spinal bone loss over 5 years, measured by dual photon absorptiometry, and radial bone loss over the first 2 years measured to quantitative computed tomography. Spinal bone loss was similar between individuals, with 94% of the variability in the data being accounted for by a statistical model that assumed parallel rates of bone loss. A less restrictive model allowing women to have different rates of spinal bone loss accounted for 12% more of the remaining variance in the data than the previous model. However, rates of radial bone loss were more dissimilar between women than rates of spinal loss. The results of the biochemical data collected serially showed that the plasma osteocalcin rose slowly to a plateau at 5 years postmenopause; in contrast, the hydroxyproline fell progressively with time over the whole period of study. These results were interpreted as being consistent with diminishing rates of bone destruction which gradually reequilibrated with bone formation as time passed after menopause.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Cross-calibration ; Dual X-ray absorptiometry (DXA) ; European Spine Phantom (ESP) ; Osteoporosis ; Quantitative computed tomography (QCT)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Up to now it has not been possible to reliably cross-calibrate dual-energy X-ray absorptiometry (DXA) densitometry equipment made by different manufacturers so that a measurement made on an individual subject can be expressed in the units used with a different type of machine. Manufacturers have adopted various procedures for edge detection and calibration, producing various normal ranges which are specific to each individual manufacturer's brand of machine. In this study we have used the recently described European Spine Phantom (ESP, prototype version), which contains three semi-anthropomorphic “vertebrae” of different densities made of simulated cortical and trabecular bone, to calibrate a range of DXA densitometers and quantitative computed tomography (QCT) equipment used in the measurement of trabecular bone density of the lumbar vertebrae. Three brands of QCT equipment and three brands of DXA equipment were assessed. Repeat measurements were made to assess machine stability. With the large majority of machines which proved stable, mean values were obtained for the measured low, medium and high density vertebrae respectively. In the case of the QCT equipment these means were for the trabecular bone density, and in the case of the DXA equipment for vertebral body bone density in the posteroanterior projection. All DXA machines overestimated the projected area of the vertebral bodies by incorporating variable amounts of transverse process. In general, the QCT equipment gave measured values which were close to the specified values for trabecular density, but there were substantial differences from the specified values in the results provided by the three DXA brands. For the QCT and Norland DXA machines (posteroanterior view), the relationships between specified densities and observed densities were found to be linear, whereas for the other DXA equipment (posteroanterior view), slightly curvilinear, exponential fits were found to be necessary to fit the plots of observed versus specified densities. From these plots, individual calibration equations were derived for each machine studied. For optimal cross-calibration, it was found to be necessary to use an individual calibration equation for each machine. This study has shown that it is possible to cross-calibrate DXA as well as QCT equipment for the measurement of axial bone density. This will be of considerable benefit for large-scale epidemiological studies as well as for multi-site clinical studies depending on bone densitometry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...