Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
  • PACS. 21.10.Re Collective levels – 23.20.Lv Gamma transitions and level energies – 27.60.+j 90 ?A? 149  (1)
  • submillimeter wave gyrotron  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 14 (2002), S. 13-16 
    ISSN: 1434-601X
    Keywords: PACS. 21.10.Re Collective levels – 23.20.Lv Gamma transitions and level energies – 27.60.+j 90 ?A? 149
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Excited states of the 119Xe nucleus have been studied by using in-beam γ-ray spectroscopy with the 107Ag ( 16O, p3n) 119Xe fusion-evaporation reaction at a beam energy of 85 MeV. The level scheme of 119Xe has been derived from γ-γ coincidence and γ-γ angular correlation analyses. We have, for the first time, established the second negative-parity favored and unfavored states built on the 11/2- state, namely the yrare rotational bands in 119Xe. In contrast to the behavior of the yrast bands where the favored states are lying lower in energy, the yrare favored states were observed to lie above the unfavored band. Such a signature inversion in 119Xe is changed to be normal at I = 12?.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 21 (2000), S. 577-592 
    ISSN: 1572-9559
    Keywords: gaussian beam ; quasi-optical system ; submillimeter wave gyrotron
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract In this paper we present a novel design of a quasi-optical system for conversion of gyrotron outputs into gaussian beams. It consists of a quasi-optical antenna, four focusing mirrors (parabolic cylinders) and a filter which removes the side lobes of the beam. The system is capable to convert three TE0n mode outputs into gaussian beams with waist size of 16.7 mm as well as four TE1n mode outputs into bi-gaussian beams with waist size of 10.9 mm in width and 16.5 mm in length.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...