Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 229-233 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused-silica capillary ; Wide bore glass capillary ; Packed column ; Plasma amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p 〈 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...