Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (8)
  • Polymer and Materials Science  (8)
Source
  • Articles: DFG German National Licenses  (8)
Material
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 24 (1986), S. 2275-2292 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A comparison of the UV absorption spectra of a carbazole-substituted N-acylated linear polyethylenimine (PEI) (5, 6) with its monomer (1, 2) and dimer (3, 4) model compounds shows the presence of local conformational order of the carbazole groups in 3, 5, and 6 since these compounds exhibit hypochromism. The UV absorption spectra of carbazole-substituted N-acrylated dehydroalanine main-chain polymer (PDA) (12, 13) and monomer (10, 11) model compounds indicate that the extent of local conformational order of the carbazole groups is reduced in 12 and 13 compared to that in 5 and 6. The UV absorption spectra of a pyrene-substituted PEI (9) and PDA (15) and those of their monomer model compounds (7, 14) indicate that the extent of local conformational order of the pyrene groups is greater in 9 than in 15 and furthermore the pyrene-substituted polymers (9, 15) show more local conformational order than analogous carbazole-substituted polymers (5, 12). The emission spectra of 5 and 12 show carbazole monomer emission, while those of 9 and 15 are dominated by pyrene excimer emission. The formation of excimer emission is more efficient in 9 than in 15. Fluorescence lifetime measurements indicate interactions of excited carbazole groups in 5 and 13 but not in 12. The quenching of carbazole fluorescence by dimethyl terephthalate is more efficient in 5 than that in 12, indicating more efficient transfer of electronic energy in 5. These measurements show that the PEI main-chain polymers are conducive to interactions of the pendant groups.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 1777-1786 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Elevated temperatures and high humidity decrease the molecular weight and impact strength of polycarbonate. Hydrolysis of injection molded polycarbonate (PC) bars stored in glass containers at 85°C and 96% relative humidity (RH) produced brown surface crystals within 30 days. Aging of PC bars at 96% RH and temperatures of 70°C and lower for longer periods of time formed a brown liquid coating on the PC. X-ray, DSC, and GPC measurements indicated that about 70 wt% of the surface crystals were bisphenol A (BPA). The remaining portion of hydrolysis products appeared to be higher molecular weight oligomers of BPA. The brown liquid was composed of supercooled liquid BPA, BPA oligomers, and water. Initial growth of BPA on the surface of a PC bar took place at the interface between the PC and the glass wall of the container. Apparently a water soluble extract from the glass container accelerated the hydrolytic degradation of PC; nevertheless, hydrolysis of PC occurred in the absence of glass - although at a slower rate. Hydrolysis studies were carried out on several commercial PC formulations. The PC resin containing only a heat stabilizer was least affected. Of the fiame retardant grades, the brominated PC hydrolyzed less rapidly than these particular compositions containing alkali metal sulfonic acid salts. A glass fiber reinforced PC was less stable than its unfilled parent compound. A hydrolytic stabilizer was ineffective against the attack of water under these conditions.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 21 (1987), S. 921-935 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Hydrogels of poly(hydroxyethyl methacrylate) (polyHEMA) homopolymer do not normally support the attachment and growth of mammalian cells. By altering the surface it has been possible to dramatically change this cell-substratum interaction so that vascular endothelial cells can attach and completely populate a poly HEMA surface. While this can be achieved by copolymerisation of polyHEMA with methacrylic acid or diethylaminoethyl methacrylate, it is most conveniently achieved by brief treatment of polyHEMA hydrogel with concentrated sulphuric acid. The resultant creation of surface - COOH groups, revealed by electron spectroscopy for chemical analysis, is consistent with the hydrolytic formation of methacrylic acid on the surface layer. Surface - COOH groups created by treatment with chloric or hydrofluoric acids were not effective. Following sulfuric acid treatment, cell adhesion and growth on polyHEMA hydrogel were better than on Teflon and approached those attained on glow-discharge-treated polystyrene. The capacity of acid-treated polyHEMA to adsorb albumin or fibronectin was of the order of 100-fold or 10-fold lower respectively than either polystyrene, Teflon, or segmented polyurethane. Hydrolytic “etching” in this way is proposed as an efficient means of expanding the use of polyHEMA hydrogel as a biomaterial without modifying the overall physicochemical properties of the bulk of the material.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 42 (1998), S. 245-257 
    ISSN: 0021-9304
    Keywords: epithelium ; migration ; topography ; porosity ; corneal epithelium ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Corneal epithelial tissue migration over the surface of a synthetic polymer can be inhibited by pores in the substrate. The effects of this substrate topography upon epithelial tissue migration were studied in vitro. Membranes of different porosities and structures were used to provide two series of surfaces having a graded increase in discontinuities: cellulose nitrate/acetate membranes with a tortuous network of pores, and track-etched polycarbonate membranes with columnar pores. Corneal epithelial tissue outgrowth was inhibited by increased pore size, and for both series of membranes, outgrowth was completely halted on membranes with mean diameter of the pores 0.9 μm at the pore densities measured. On the track-etched membranes with pores of 〈0.9 μm diameter, tissue outgrowth could be partially “rescued” by coating with fibronectin or collagen, but above this size, the inhibition predominated. The effect of porosity of the track-etched membranes upon the migration of dissociated epithelial cells was also examined. Although migration of these cells was reduced on membranes having pore sizes larger than 0.9 μm, it was not completely inhibited even on membranes of 2.3-μm pore diameter. Therefore, tissue movement of adult stratified epithelium may be inhibited by specific surface topographies, and in this assay system, epithelial tissue outgrowth was more affected than was the migration of dissociated epithelial cells. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 245-257, 1998.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ferrous based, corrosion resistant amorphous alloys supported the adhesion and growth of cultured chick neuronal cells, human marrow stromal cells (presumptive osteoblasts), bovine aortal endothelial cells, and hamster kidney fibroblasts. Alloys of compositions Fe60Ni10Cr10P13C7, Fe70Cr10P13C7, and Fe70Cr10P13B7 were found to be suitable. In contrast the crystalline form of these alloys was markedly less effective. Outgrowth of neurites from neuronal cells was promoted by precoating the metal surface with either laminin or neurite promotion factor. The adhesion of osteoblasts and fibroblasts suggests that corrosion resistant metal glasses should be considered as biomaterials useful for orthopedic applications. The adhesion of neuronal cells accompanied by neurite outgrowth indicates that the system might provide a functional interface between the neuromuscular system and an electromagnetic material that could be useful in bionic engineering.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 22 (1988), S. 963-976 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We report here the use of perfluorosulfonic acid (Nafion) as a substratum for the growth of bovine aortal endothelial cells. This support which can be generated in a number of forms is at least as efficient in maintaining the growth of endothelial and other cell types as tissue culture grade polystyrene (TCP) and represents and advance in this regard over polytetrafluoroethylene (Teflon). The mechanism underlying the different cell attachment capacities of these three polymers is not readily related to their different protein binding patterns. While Nafion adsorbs more total protein from serum than Teflon or TCP, it adsorbs relatively less of the major cell adhesive proteins, vitronectin and fibronectin, than does Teflon. Both Nafion and Teflon had comparable but low thrombogenic potential by in vitro tests. Teflon or expanded Teflon (Gore-tex) coated with a thin film of Nafion assumes the cell supportive characteristics of Nafion and hence the modification of these surfaces by the induction of a stable bond between Teflon (in various forms) and Nafion may provide a composite vascular graft material which has all the desirable qualities of both materials.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 54 (1961), S. 229-240 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Conductivity measurements of solutions of sodium polymethacylate (PMA), sodium carboxymethyl cellulose (CMC), and sodium alginate (AA) are presented. Measurements were made in the frequency range of 1 to 30 Mcycles/sec. The increment of electrical conductivity is taken as a measure of the dielectric loss occurring in the solution. The theories of Debye,1 Debye-Falkenhagen,2 Maxwell-Wagner,3 and the recent ionic model proposed by O'Konski4 are discussed and it is shown that the results can be satisfactorily explained only with an ionic model of the form of O'Konski's. Previous work is shown to fit in satisfactorily with this theory. In a few cases measurements of loss factors and dielectric constants are presented, and are shown to give additionnal support to the model of O'Konski.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Polymer Science 54 (1961), S. 241-252 
    ISSN: 0022-3832
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Measurements of the dielectric constants and dielectric loss factors of aqueous solutions of potassium chondroitin sulfate, poly-L-lysine hydrobromide, sodium ribonucleate, sodium desoxyribonucleate, and two polymetaphosphates, Calgon glass and Maddrell salt, are presented. The data are analyzed by the Cole-Cole are method1 and relaxation times are calculated by the method of Zaromb.2 Except in the case of sodium ribonucleate the solutions are shown to behave as linear polyelectrolytes and the data are shown to fit the ionic model proposed by O'Konski.3 Sodium ribonucleate does not show the characteristics of a linear polyelectrolyte but appears to behave more like a protein in solution.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...