Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Simultaneous curve fitting for the ionization parameters of oxidized and reduced horse heart cytochrome c in 0.15M KCl and 20°C yields values for the ionization constants (as pK′) and the heats of ionization (ΔHi) which can reconstruct either the potentiometric or thermal titration curves. Reduced cytochrome c requires 8 sets of groups, whereas oxidized cytochrome c requires 10 sets of groups. The additional groups in the oxidized preparation appear to involve the ferriheme (pK′, 9.25; ΔHi, 13.7 kcal/mol) and a tyrosine (pK′ ≃ 10.24) that is not present in the reduced form. The potentiometric and thermal difference curves (reduced - oxidized) involve the appearance of 17 kcal/mol centered at pH 9.7 and 5.8 kcal/mol centered at pH 4.9. The carboxyl groups in both species appear to be normal for the hydrogen-bonded form. Only one histidine has normal ionization properties (pK′, 6.7; ΔHi, 7.5 kcal/mol), as do 17 of the lysine residues (pK′, 10.8; ΔHi, 11.5 kcal/mol).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 19 (1980), S. 885-898 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Potentiometric titration curves of oxidized and reduced horse heart cytochrome c in 0.15M KCl at 20°C have been obtained by timed titration (0.125-0.500 μmol/sec) from the isoionic points (pH 10.2-10.4) to pH 3 and back to the isoionic point. Computer-assisted (PROPHET) data acquisition and blank corrections give curves with good precision with a maximum standard deviation of 0.3 groups for an average error of 1%. The potentiometric titration curve of reduced cytochrome c is reversible within the precision of the method and for the pH range studied. The potentiometric curves for oxidized cytochrome c titrated upscale (pH 3-10) and downscale (pH 10-3) are not reversible. However, they show the same ionization behavior after the initial downscale titration. This is probably the result of a conformational change. Comparison of the data herein reported with the titration curves of oxidized cytochrome c already published by others indicates good agreement on the basis of a normalization of the concentration of protein or on the basis of 25 titrable groups between the acid end point and the isoionic pH.Titration of the 2 μmol imidazole in the upscale or downscale direction gives the correct analytical concentration and pK′ after correction for the solvent titration. Titration of reduced cytochrome c in the presence and absence of an additional equivalent of imidazole gave a difference titration curve, which indicates that a group on the protein shifts from pK′ 5.8 to pK′ 5.3 in the presence of imidazole. The pK′ of imidazole, in the presence of the protein, remains at a nearly normal value of 7.34.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 19 (1980), S. 899-911 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The heats of ionization of protons, ΔHi, of oxidized and reduced horse heart cytochrome c in 0.15M KCl at 20°C were determined using a titration calorimeter which simultaneously afforded the potentiometric titration curve. Reproducibility of the thermal titrations is within 2%, and evaluation of the heats observed after the heat loss corrections is estimated to be within 5%. A single titration of oxidized cytochrome c from pH 11 to 3 is in excellent agreement with the thermal titration of this protein obtained with flow calorimetry. The thermal titration, however, is not reversible, due in part to the loss of titratable group(s) in this pH region and to the heat contribution of the acid and alkaline conformational changes which occur. Although of lesser magnitude, the reduced form also indicates similar thermal transitions. These differences are due solely to conformational contributions to the thermal process, since the potentiometric curves are reversible. The nature of the irreversibility for oxidized cytochrome c appears to involve the loss of a group with pK′ 8.9 and the shift of two groups from pK′ 5.6 to 4.8. Thermal difference curves for this process indicate that heats of -7.8 and -24.1 kcal/mol are liberated which are centered at pH 9.3 and 3.9, respectively.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...