Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1229-1230 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 511-518 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To evaluate the effect of surface treatment and surface microtexture on cellular behavior, smooth and microtextured silicone substrata were produced. The microtextured substrata possessed parallel surface grooves with a width and spacing of 2.0 (SilD02), 5.0 (SilD05), and 10 μm (SilD10). The groove depth was approximately 0.5 μm. Subsequently, these substrata were either left untreated (NT) or treated by ultraviolet irradiation (UV), radiofrequency glow discharge treatment (RFGD), or both (UVRFGD). After characterization of the substrata, rat dermal fibroblasts (RDF) were cultured on the UV, RFGD, and UVRFGD treated surfaces for 1, 3, 5, and 7 days. Comparison between the NT and UV substrata revealed that UV treatment did not influence the contact angles and surface energies of surfaces with a similar surface topography. However, the contact angles of the RFGD and UVRFGD substrata were significantly smaller than those of the UV and NT substrata. The dimension of the surface microevents did not influence the wettability characteristics. Cell culture experiments revealed that RDF cell growth on UV-treated surfaces was lower than on the RFGD and UVRFGD substrata. SEM examination demonstrated that the parallel surface grooves on the SilD02 and SilD05 substrata were able to induce stronger cell orientation and alignment than the events on SilD10 surfaces. By combining all of our findings, the most important conclusion was that physicochemical parameters such as wettability and surface free energy influence cell growth but play no measurable role in the shape and orientation of cells on microtextured surfaces. © 1995 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: surface topography ; actin ; vinculin ; fibronectin ; vitronectin ; grooves ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The microfilaments and vinculin-containing attachment complexes of rat dermal fibroblasts (RDF) incubated on microtextured surfaces were investigated with confocal laser scanning microscopy (CLSM) and digital image analysis (DIA). In addition, depositions of bovine and endogenous fibronectin and vitronectin were studied. Smooth and microtextured silicone substrata were produced that possessed parallel surface grooves with a groove and ridge width of 2.0, 5.0, and 10.0 μm. The groove depth was approximately 0.5 μm. CLSM and DIA make it possible to visualize and analyze intracellular and extracellular proteins and the underlying surface simultaneously. It was observed that the microfilaments and vinculin aggregates of the RDFs on the 2.0 μm grooved substrata were oriented along the surface grooves after 1, 3, 5, and 7 days of incubation while these proteins were significantly less oriented on the 5.0 and 10.0 μm grooved surfaces. Vinculin was located mainly on the surface ridges on all textured surfaces. In contrast, bovine and endogenous fibronectin and vitronectin were oriented along the surface grooves on all textured surfaces. These proteins did not seem to be hindered by the surface grooves since many groove-spanning filaments were found on all the microgrooved surfaces. In conclusion, it can be said that microtextured surfaces influence the orientation of intracellular and extracellular proteins. Although results corroborate three earlier published hypotheses, they do not justify a specific choice of any one of these hypotheses. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 291-300, 1998.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 41 (1998), S. 41-48 
    ISSN: 0021-9304
    Keywords: plasma spray ; titanium ; surface roughness ; bone reaction ; implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the biological and mechanical response of bone to titanium plasma-sprayed implants of different roughnesses. Three types of titanium plasma-spray coating were applied to beam-shaped implants: Ti2, Ti3, and Ti4, with a Ra of 16.5, 21.4, and 37.9 μm, respectively. An Al2O3 grit-blasted implant (Ti-un) with a Ra of 4.7 μ was used as a control. In total, 72 implants were inserted in the tibial cortical bone of nine adult female goats. These implants were evaluated histologically and mechanically 3 months after implantation. At the end of the experiment, of the 72 inserted implants, two implants (one Ti2 and one Ti4) were lost. Histological evaluation of the other retrieved implants revealed a uniform bone reaction for all implants. The unloaded plasma-spray coatings showed no signs of delamination at the implant-coating interface. Occasionally, particles of the Ti4 coating broke free and were found near the implant. Histomorphometry revealed no difference in bone contact for the different implants (P 〉 0.05). Furthermore, the push-out test showed no significant difference (P 〉 0.05). Linear regression showed no interaction between the push-out values and the roughness values (r = 0.5). On the basis of these results, it may be concluded that the used surface roughnesses did not lead to differences in bone response or mechanical attachment strength in goat cortical bone. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 41-48, 1998.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0021-9304
    Keywords: surface topography ; plasma etching ; cellular orientation ; focal adhesion point ; in vitro ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During this study, microtechnology and plasma etching were used to produce gratings 1.0 (TiD01), 2.0 (TiD02), 5.0 (TiD05), and 10.0 μm wide (TiD10) into commercially pure titanium wafers. After incubation of rat dermal fibroblast (RDFs) on these surfaces for 3 days, the cells were observed with scanning electron (SEM), transmission electron (TEM), and confocal laser scanning microscopy (CLSM). Results showed that the RDFs as a whole and their stress fibers oriented strictly parallel to the surface pattern on the TiD01 and TiD02 surfaces. On the TiD05 and TiD10 surfaces, this orientation was not observed. In addition, TEM and CLSM demonstrated that the focal adhesion points (FAP) were located mainly on the surface pattern ridges. TEM revealed that FAP were wrapped occasionally around the edges of the ridges. Only the RDFs on both the TiD05 and TiD10 surfaces protruded into the grooves and possessed FAP on the walls of the grooves. Attachment to the groove floor was observed only on the TiD10 textures. Comparison of these results with earlier observations on microtextured silicone rubber substrata suggests that material-specific properties do not influence the orientational effect of the surface texture on the observed RDF cellular behavior. The proliferation rate of the RDFs, however, seems to be much higher on titanium than on silicone rubber substrata. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 425-433, 1998.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 42 (1998), S. 266-271 
    ISSN: 0021-9304
    Keywords: calcium phosphate ; ion beam analysis ; coating ; Rutherford backscattering ; elastic recoil detection ; biomaterial ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: RF magnetron sputter deposition was used to deposit thin calcium phosphate (hydroxyapatite) layers on titanium alloy substrate material. We determined the precise amount of calcium, phosphorus, oxygen, and hydrogen in these films by combining two ion-beam analysis techniques: Rutherford backscattering spectrometry (RBS) and elastic recoil detection (ERD). Variables were power level, partial oxygen pressure, or additional water vapor. Also examined was the influence of additional bias power to the substrates during deposition and the effect of annealing on the final composition of the deposited layers. Measurements showed that the Ca/P ratio decreased with increasing oxygen pressure or decreasing sputtering power. In addition, the Ca/P ratio increased when a bias was applied to the substrates. The O/P ratio of the films decreased with additional oxygen pressure but increased when additional water vapor was applied during deposition. All as-deposited films showed a higher hydrogen content than stoichiometric HA. The hydrogen content in the films deposited with water vapor was more than 7 times higher than in the films deposited under pure argon conditions. After annealing, the hydrogen content decreased to about 3.5 at % whereas in stoichiometric HA the hydrogen content amounts to 4.5 at %. After annealing, the oxygen concentration in the film also decreased. We assume that hydrogen disappears out of the film as H2O during annealing. For the targets used in these experiments, sputter deposition at 400 W, with additional water vapor and annealing at 500°C, produced films with a stoichiometry closest to that of hydroxyapatite. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 266-271, 1998.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 295-307 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on certain aspects of wound-healing around percutaneous implants. Plasma-sprayed and dense hydroxylapatite, titanium, and carbon test implants were inserted into the tibia and the cranium of 12 rabbits. Four and 8 months after insertion, the animals were sacrificed and the implants with their surrounding tissues were processed histologically. Light- and transmission electron microscopic investigations were performed. It is found that direct and indirect boneanchoring favors the longevity of percutaneous implants. No differences in tissue reaction between the various implant materials were observed.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 1535-1545 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The objective of this study was to evaluate a new type of percutaneous device (PD) designed to be implanted in soft tissues. The new PD consisted out of: (1) a flange-shaped subcutaneous component, made from sintered titanium fiber-web, and (2) a percutaneous component, made from dense sintered hydroxyapatite. The PDs were inserted in the back of 15 rabbits. The surgical procedure was performed in two steps. In the first session the subcutaneous component was placed. In the second session, after 3-4 months the percutaneous component was fixed in the subcutaneous component. The implants were left in situ for 1 and 4 months after the second implantation session. Clinical and histological investigations were performed. It is found, that there was only a limited epidermal downgrowth in the percutaneous area. No inflammatory reaction was observed in the dermal connective tissue. Histological analysis also demonstrated that titanium fiber mesh evokes minor adverse effects of the surrounding tissues. In conclusion, these experiments have shown that stabilization of the PD in the hypodermal area by using a sintered titanium fiber-web structure favors the longevity of PDs implanted in soft tissues.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...