    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 59-63 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The release behavior of typical commercial tissue expanders has been examined by carrying out two kinds of experiments: (1) Determination of chemical nature and its modification after in vivo use by X-ray photoelectron spectroscopy for chemical analysis. This study has been parallelled by scanning electron microscopy with associated energy dispersive X-ray analysis of surface, as well as by silicon compounds analysis of tissues around implants. (2) Kinetic examination of silicon compounds released by the biomaterial in physiologic solution at 36 ± 0.3°C. Results of these investigations have shown independently that the starting material was not a filler-free, pure polymer, but a composite, reinforced elastomer, with the reinforcing agent most seemingly represented by silicon dioxide. Release of latter, with a relatively fast kinetics, is compatible with data of the simulating laboratory runs in the physiologic solution. All these facts seem to rule out any hypothesis of a prevailing siloxane oligomer migration. The correlation of kinetic and physicochemical tests with the in vivo behavior is discussed. © 1995 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1157-1163 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A commercial polyester acrylate prepolymer, to which a 2:3 wt/wt ratio of tripropyleneglycol diacrylate was added to increase photopolymerization rate, was employed as photochemical conjugating agent, through photografting. 1,2-Diphenyl,2,2-dimethoxyethanone was added as standard photoinitiator (7.0 wt/wt%), together with varying amounts (0.003-4.0 wt/wt%) of some proprietary photocatalytic systems, based on the following photocataiysts: m̈-peroxobis [N,N′-ethylene-bis(salicylideneiminato)cobalt](III) (I), vanadium (V) triethoxide (II), and a synergic mixture of vanadium (V) tri-t-butoxide and tri-i-propoxide (III). A homogeneous suspension containing (10 ± 2) × 105 human thyroid follicular cells per milliliter of photochemically reacting medium was photografted, at a surface density of 6.5 ± 0.7 mg · cm -2 of diacrylate prepolymer mixture, onto polystyrene plates or onto commercial microfiltration and ultrafiltration membranes consisting of nonwoven cellulose tissues with known porosities varying between 5 and 30 m̈m and in photografted polyester acrylate-based membranes with a cutoff of 50 ± 5 KD. Bioconjugation yields, as a function of photografting time, were measured gravimetrically and by multiple internal reflection IR spectroscopy. Three series of experiments were performed: (1) measurements of graft yields of the prepolymer, and of the parallel disappearance of double bonds, in the absence of mammalian cells; (2) the same as (1), in the presence of thyroid follicular cells; (3) the same as (2), but with the photoinitiating system formed by the standard photoinitiator alone, with no photocatalyst. Results show that if a suitable photocatalyst is not added, no practical conjugation is possible. An appropriate choice of the photocatalytic system and of its concentration allows reduction of irradiation times (e. g., by a factor of about 2 × 104 calculated as the mean lifetime ratio, between the uncatalyzed system and that with 0.1 wt% of [III]), thus minimizing cell inactivation and/or improving responsiveness to the bioassay. From this point of view, photoactivity of (III) is outstanding. The very small, but clearly perceptible, influence of polymeric support on bioconjugation is also commented upon. © 1994 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...