    Materials and Corrosion/Werkstoffe und Korrosion 32 (1981), S. 435-442 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Corrosion of galvanized and unalloyed steel tubes in drinking water of different hardness and increased neutral salt contentThe corrosion of galvanized and unalloyed steel tubes in drinking water of different hardness was studied at the Rheinau water works, Mannheim. The criteria to describe the influence of the water quality parameters were the decrease of the metallic zinc layer, the composition of the corrosion products and a visual qualification of the coatings.The main parameters influencing zinc corrosion are pH-value and flowrate. Comparison with other data shows no significant effect of buffer intensity and neutral salt concentration. The layer of corrosionproducts in unalloyed steel tubes showed qualitative and quantitative differences with different hardness. The most important effect can be seen in the different contents of calcite in the coating. Low buffer capacity decreased the quality of the corrosion product layer.The results lead to the conclusion, that softening should he limitated to a certain level, otherwise corrosion problems will increase.
    Notes: Das Korrosionsverhalten von Hausinstallationsrohren aus verzinktem Stahl und unlegiertem Stahl wurde im Rahmen von Feldversuchen im Wasserwerk Rheinau der Energie- und Wasserwerke Rhein Neckar AG, Mannheim, an drei unterschiedlich harten Wässern untersucht.Dabei erfolgte die Erfassung des Einflusses der verschiedenen Wasserqualitäten durch Bestimmung des Zinkabtrags, die Erfassung der Korrosionsprodukte an den Rohrinnenoberflächen und durch eine optische Beurteilung der Deckschichtqualitäten.Die Messungen zum Zinkabtrag zeigten einen eindeutigen Einfluß des pH-Wertes and der Fließgeschwindigkeit. Dagegen konnte kein Hinweis auf einen signifikanten Einfluß der Pufferung und des Neutralsalzgehaltes beobachtet werden. Für die Deckschichtbildung am unlegierten Stahlrohr warden dagegen sowohl qualitative, wie auch quantitative Unterschiede zwischen verschieden weit enthärteten Wässern festgestellt, wobei vor allem große Unterschiede im Calciumkarbonatgehalt der Deckschichten beobachtet wurden. Eine weitgehende Enthärtung führt zu einer deutlichen Verminderung der Qualität der gebildeten Deckschichten.Die Ergebnisse gestatten Folgerungen über die Grenzen der speziellen Fragestellung in Mannheim hinaus für den Einsatz einer zentralen Teilenthärtung.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 34 (1983), S. 107-111 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Measurement of iron-pickup by potable water - A new method for the assessment of surface layers in black steel pipingRed water in drinking water distribution systems causes problems for the water companies because of the consumers pretension to get drinking water of high quality. The corrosion products in the water are normally iron compounds, which arise from the corrosion process and diffuse through the surface layer into the aqueous phase. With the proposed method, the increase of the iron concentration in the water and parallel the corrosion rate, by the determination of the differential oxygen demand, is measured. This allows to make direct statements with regard to the protective qualities of the surface layer.
    Notes: Das Aufteten von Rostwasser bei der Verteilung von Trinkwasser in Rohrleitungen aus ungeschützten Eisenwerkstoffen gehört zu den Korrosionsproblemen, die im Gegensatz stehen zu dem Anspruch des Verbrauchers auf ein qualitative hochwertiges Trinkwasser. Die Ursachen für diesen Korrosionsschaden sind in der Qualität der sich an der Rohrinnenwandung aufbauenden Deckschicht zu suchen. Mit der hier beschriebenen Methode zur Messung der Aufeisenung wird ein Verfahren vorgeschlagen, das in Verbindung mit der parallel über die Sauerstoffdifferenzmessung zu bestimmenden Korrosionsrate eine direkte Beurteilung der Deckschichtqualitäten hinsichtlich ihrer schützenden Eigenschaften ermöglicht.