Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Pressure support ventilation  (2)
  • Ossification of ligamentum flavum  (1)
  • 1
    ISSN: 1432-1238
    Schlagwort(e): Work of breathing ; Pressure support ventilation ; Lung model ; Artificial ventilation ; Ventilators ; Trigger delay
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective The triggering capability of both the pressure and flow triggering systems of the Servo 300 ventilator (Siemens-Elema, Sweden) was compared at various levels of positive end-expiratory pressure (PEEP), airway resistance (Raw), inspiratory effort and air leak, using a mechanical lung model. Design The ventilator was connected to a two bellows-in-series-type lung model with various mechanical properties. Lung complicance and chest wall compliance were 0.03 and 0.12 l/cmH2O, respectively. Raw was 5, 20 and 50 cmH2O/l/s. Respiratory rate was 15 breaths/min. To compare the triggering capability of both systems, the sensitivity of pressure and flow triggered pressure support ventilation (PSV) was adjusted to be equal by observing the triggering time at 0 cmH2O PEEP and 16 cmH2O of pressure support (PS) with no air leak. No auto-PEEP was developed. In the measurement of trigger delay, the PS level ranged from 16 to 22 cmH2O to attain a set tidal volume (VT) of 470 ml at a Raw of 5, 20 and 50 cmH2O/l/s. The PEEP level was then changed from 0, 5 and 10 cmH2O at a PS level of 17 cmH2O and Raw of 5 and 20 cmH2O/l/s, and the trigger delay was determined. The effect of various levels of air leak and inspiratory effort on triggering capability was also evaluated. Inspiratory effort during triggering delay was estimated by measurements of pressure differentials of airway pressure (Paw) and driving pressure in the diaphragm bellows (Pdriv) in both systems. Measurements and results There were no significant differences in trigger delay between the two triggering systems at the various PEEP and Raw levels. At the matched sensitivity level, air leak decreased trigger delay in both systems, and additional PEEP caused auto-cycling. A low inspiratory drive increased trigger delay in the pressure sensing system, while trigger delay was not affected in the flow sensing system. The Paw and Pdriv differentials were lower in flow triggering than in pressure triggering. Conclusions With respect to triggering delay, the triggering capabilities of the pressure and flow sensing systems were comparable with and without PEEP and/or high air-way resistance at the same sensitivity level, unless low inspiratory drive and air leak were present. In terms of pressure differentials, the flow triggering system may require less inspiratory effort to trigger the ventilator than that of the pressure triggering system with a comparable triggering time. However, this difference may be extremely small.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1238
    Schlagwort(e): Key words Work of breathing ; Pressure support ventilation ; Lung model ; Artificial ventilation ; Ventilators ; Trigger delay
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: The triggering capability of both the pressure and flow triggering systems of the Servo 300 ventilator (Siemens-Elema, Sweden) was compared at various levels of positive end-expiratory pressure (PEEP), airway resistance (Raw), inspiratory effort and air leak, using a mechanical lung model. Design: The ventilator was connected to a two bellows-in-series-type lung model with various mechanical properties. Lung complicance and chest wall compliance were 0.03 and 0.12 l/cmH2O, respectively. Raw was 5, 20 and 50 cmH2O/l/s. Respiratory rate was 15 breaths/min. To compare the triggering capability of both systems, the sensitivity of pressure and flow triggered pressure support ventilation (PSV) was adjusted to be equal by observing the triggering time at 0 cmH2O PEEP and 16 cmH2O of pressure support (PS) with no air leak. No auto-PEEP was developed. In the measurement of trigger delay, the PS level ranged from 16 to 22 cmH2O to attain a set tidal volume (VT) of 470 ml at a Raw of 5, 20 and 50 cmH2O/l/s. The PEEP level was then changed from 0, 5 and 10 cmH2O at a PS level of 17 cmH2O and Raw of 5 and 20 cmH2O/l/s, and the trigger delay was determined. The effect of various levels of air leak and inspiratory effort on triggering capability was also evaluated. Inspiratory effort during triggering delay was estimated by measurements of pressure differentials of airway pressure (Paw) and driving pressure in the diaphragm bellows (Pdriv) in both systems. Measurements and results: There were no significant differences in trigger delay between the two triggering systems at the various PEEP and Raw levels. At the matched sensitivity level, air leak decreased trigger delay in both systems, and additional PEEP caused auto-cycling. A low inspiratory drive increased trigger delay in the pressure sensing system, while trigger delay was not affected in the flow sensing system. The Paw and Pdriv differentials were lower in flow triggering than in pressure triggering. Conclusions: With respect to triggering delay, the triggering capabilities of the pressure and flow sensing systems were comparable with and without PEEP and/or high airway resistance at the same sensitivity level, unless low inspiratory drive and air leak were present. In terms of pressure differentials, the flow triggering system may require less inspiratory effort to trigger the ventilator than that of the pressure triggering system with a comparable triggering time. However, this difference may be extremely small.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Neuroradiology 30 (1988), S. 571-573 
    ISSN: 1432-1920
    Schlagwort(e): Magnetic resonance imaging ; Ossification of ligamentum flavum ; Thoracic myelopathy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary A case of thoracic myelopathy due to ossification of the ligamentum flavum is presented. A fifty-five year old female complained of sensory and motor disturbance of lower limbs. Neuroradiologically, in addition to ossification of the posterior longitudinal ligament throughout the spines, ossified ligamenta flava were found at the Th10–11 level and magnetic resonance imaging (MRI) clearly showed the spinal cord compressed at the same level by a low-intensity-signal lesion. Laminectomy and removal of the ossfied ligamenta flava improved her neurological dysfunction. The usefulness of the MRI in the neuroradiological diagnosis was confirmed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...