Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Polymer and Materials Science  (2)
  • Pyrex glass  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Electroanalysis 8 (1996), S. 880-884 
    ISSN: 1040-0397
    Schlagwort(e): Carbon paste ; Nafion-loaded electrode ; Alkaline phosphatase ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The indirect electrochemical determination of alkaline phosphatase was achieved with a detection limit of 2 Ul-1 at a fresh surface of a renewable Nafion-loaded carbon paste electrode, without preconditioning. [N-ferrocenoyl]-4-aminophenyl phosphate was used as substrate and the enzyme reaction proceeded for 15 min in Tris buffer at pH 9.0. [N-ferrocenoyl]-4-aminophenol was thus generated, which was further preconcentrated at the modified carbon paste electrode during a 5 min accumulation step in neutral medium. A potential of 0.35 V was applied during this step, and so the substituted phenol was irreversibly entrapped as a ferrocenium salt within Nafion before being detected by square wave voltammetry.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1040-0397
    Schlagwort(e): Methyl viologen ; Pyrex glass ; Adsorption ; Nafion ; Renewable electrode ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Square wave voltammograms of methyl viologen (MV2+) were recorded at a renewable Nafion-loaded carbon paste electrode immersed in 20 mL of phosphate buffer solution (pH 7.4) contained in a beaker-type electrochemical cell (Pyrex glass; contact area = 33 cm2). From the calibration plot obtained in the concentration range 0.01-2.4 μM, it could be concluded that the maximum surface excess of MV2+ adsorbed on Pyrex glass (0.24 nmol cm-2) was reached at concentrations above 1.4 μM. The adsorption isotherm presented a sigmoidal shape characteristic of attractive interaction. From this plot, it was evaluated that the maximum depletion of MV2+ in solution (28%) did not occur at the lowest concentrations, but in nearly micromolar solutions. This result emphasizes the unavoidable and random errors which are involved when MV2+ solutions are purposely diluted in Pyrex glassware. The MV2+ adsorption proceeds to a less extent on Duran borosilicate glass and/or in acid or alkaline medium.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...