Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 301 (1968), S. 292-301 
    ISSN: 1432-2013
    Keywords: Kinetics of Hemoglobin ; O2 Uptake Time of the Erythrocyte ; Contact Time ; O2 Diffusion and Chemical Reaction ; Reaktionskinetik des Hämoglobins ; O2-Aufnahmezeit des Erythrocyten ; Kontaktzeit ; O2-Diffusion und chemische Reaktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In Modellversuchen werden der Zeitbedarf und die Übergangsfunktion für die O2-Aufnahme des Blutes unter den Bedingungen in der Lungencapillare untersucht. Dabei werden Blutlamellen, bestehend aus einer einlagigen Erythrocytenschicht und beidseitigem Plasmarand, einem plötzlichen Wechsel der O2- und CO2-Partialdrücke ausgesetzt. Ein Teil der Lamellen ist zwischen zwei, wenige Mikron dicken Cellophanmembranen gelagert, um den Einfluß eines Diffusionshindernisses auf den O2-Aufnahmemodus der Erythrocyten zu erfassen. Die Untersuchungen ergeben: 1. Bei der O2-Aufnahme unter „Normoxiebedingungen“ erfolgt die Hälfte der Sättigungsänderung im Erythrocyten in 0,02 sec, unter „Hypoxiebedingungen“ in 0,09 sec. Die tatsächlichen O2-Aufsättigungszeiten in der Lunge sind jedoch wegen Verzögerung durch die vorgeschaltete alveolo-capilläre Membran um etwa das 1,3 fache verlängert. Unter Berücksichtigung dieses Faktors läßt sich bei einer angenommenen $${\text{Ac'D}}_{{\text{O}}_{\text{2}} } $$ von 6 mm Hg im „Hypoxiebereich“ eine alveoläre Kontaktzeit zwischen Erythrocyt und Gasphase von 0,26 sec berechnen. 2. Der O2-Aufsättigungsmodus der Blutlamellen mit vorgeschalteter Membran folgt einer Exponentialfunktion. Die Kenntnis dieses exponentiellen Verlaufs der O2-Aufnahme liefert die Grundlage für eine einfache Berechnung der O2-Diffusionskapazität.
    Notes: Summary The time constant and transient function for the O2 uptake of the blood, under conditions similar to those in the lung capillary, are examined by means of experiments on models. In the process, blood lamellas, consisting of a single layer of erythrocytes with a plasma layer on both sides, are exposed to sudden changes in the O2 and CO2 partial pressures. Some of the lamellas are placed between two cellophane membranes, each only a few microns thick, in order to determine the influence of a resistance to diffusion on the O2 uptake process. The experiments show that: 1. During the O2 uptake process under “normoxia conditions”, half of the saturation change in the erythrocyte takes place within 0.02 sec, and under “hypoxia conditions”, within 0.09 sec. The actual O2 saturation times in the lung, however, are extended to about 1.3 times by the alveolar-capillary membrane. Taking this factor into consideration, an alveolar contact time of 0.26 sec between the erythrocyte and gas phase, is obtained, if an $${\text{Ac'D}}_{{\text{O}}_{\text{2}} } $$ of 6 mm Hg in the “hypoxia range” is assumed. 2. The O2 saturation process of the blood lamellas with membranes connected in series follows an exponential function. This exponential shape of the O2 uptake provides a basis for the simple calculation of the O2 diffusing capacity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 301 (1968), S. 302-310 
    ISSN: 1432-2013
    Keywords: Bohr shift ; Rapidity of CO2 Exchange ; Carbonic Anhydrase ; Kinetics of Hemoglobin ; Bohr-Effekt ; Geschwindigkeit des CO2-Austausches ; Carboanhydrase ; Reaktionskinetik des Hämoglobins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird der zeitliche Ablauf des Bohr-Effektes an dünnen Blutlamellen, bestehend aus einer einlagigen Erythrocytenschicht mit beidseitigem Plasmarand, untersucht. Die einer plötzlichen Änderung des CO2-Druckes folgende O2-Sättigungsänderung des Hämoglobins wird bei 37° C im Bereich zwischen $$S_{{\text{O}}_{\text{2}} } = 83\% $$ und 49% in beiden Richtungen durchgeführt und photometrisch analysiert. Dabei ergibt sich: 1. Die Zeit für den Anstieg der O2-Sättigung der Blutlamelle ist etwa sechsmal länger als die für die O2-Entsättigung. Die mittleren Halbwertzeiten betragen 0,97 bzw. 0,17 sec. 2. Der O2-Entsättigungsvorgang nach einer CO2-Druckerhöhung benötigt fast die gleiche Zeit wie die im selben Bereich ablaufende Entsättigung nach einer O2-Druckerniedrigung. Daraus folgt, daß die O2-Diffusionsrate den CO2-Austausch in dieser Richtung zeitlich begrenzen kann. 3. Der längere O2-Aufsättigungsprozeß nach einer CO2-Druckerniedrigung hängt in seinem zeitlichen Ablauf von der Menge des ausgetauschten HCO 3 − ab. Bei größeren CO2-Sprüngen kann die Hamburger-Shift den Bohr-Effekt zeitlich begrenzen.
    Notes: Summary The time course of the Bohr effect on thin blood lamellas, consisting of a single layer of erythrocytes with a plasma layer on both sides, is examined. The O2 saturation change of the hemoglobin, following a sudden change in the CO2 pressure, is carried out in both directions at a temperature of 37° C, within the range $$S_{{\text{O}}_{\text{2}} } = 83\% $$ and 49%, and photometrically analyzed. The analysis shows that: 1. The time needed for the increase in the O2 saturation of the blood lamellas is approximately 6 times greater than that required by the O2 desaturation process. The average half-value times are 0.97 sec and 0.17 sec, respectively. 2. The O2 desaturation process, following a CO2 pressure increase, needs almost as much time as a desaturation process in the same range, after an O2 pressure decrease. Hence, it follows that the O2 diffusion rate can temporally limit the CO2 exchange in this direction. 3. After a CO2 decrease, the time course of the longer O2 saturation process depends on the quantity of HCO 3 − inside the erythrocyte. When there is a considerable CO2 jump, the Hamburger shift can temporally limit the Bohr effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 277 (1985), S. 484-488 
    ISSN: 1432-069X
    Keywords: Mechanical properties ; Repeated strain in vivo ; Time dependence of recovery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new method was developed to study the in vivo recovery of mechanical properties of rat skin after repeated strain. Full recovery, i.e., restitutio ad integrum, can be observed only in in vivo experiments but not in in vitro conditions. For the in vivo studies, tabs were fastened on the back skin of rats to test stress-strain behaviour both perpendicular and longitudinal to the body axis. Under anesthesia, skin was extended repeatedly 30 times to an elongation of up to 50% of the distance between the tabs. The experiment was repeated in the same animals at either 0.5, 1, 6, or 16 h. Differences depending on the direction of stretching versus body axis were observed during the first run. A decrease in stress values depending on the logarithm of the number of cycles was found, in both directions, to be attributable to the relaxation phenomenon. The measured stress values after 0.5, 1, and 6 h were considerably lower compared to the first run, thus indicating an incomplete recovery. After 16 h, an almost complete recovery was observed, so that, in perpendicular samples, even higher values were observed, thus indicating an overshooting of the repair mechanisms. The difficulties associated with obtaining appropriate physical and mathematical models for the mechanical properties of skin are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 244 (1972), S. 130-134 
    ISSN: 1432-069X
    Keywords: Cutis ; Corium ; Epidermis ; Mechanical properties ; In vivo ; In vitro
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 262 (1978), S. 15-25 
    ISSN: 1432-069X
    Keywords: Repeated UV-irradiation ; Skin ; Hairless mouse ; Mechanical properties ; Collagen ; Elastin ; Wiederholte UV-Bestrahlung ; Haut ; Haarlose Maus ; Mechanische Eigenschaften ; Collagen ; Elastin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An der Haut von haarlosen Mäusen wurde die Wirkung von wiederholter UV-Bestrahlung auf mechanische und biochemische Parameter untersucht. Eine tägliche UV-A-Bestrahlung über 1 h während 8 Wochen verursachte nur eine leichte Zunahme der Hautdicke und eine Abnahme der Dehnung beim Abriß. Nach UV-B- bzw. UV-C-Bestrahlung waren die Veränderungen jedoch sehr viel drastischer. In diesen Untersuchungsreihen wurden die Mäuse mit einer UV-Lampe im Abstand von 17 cm bestrahlt, so daß die Bestrahlungsintensität 20 mW/cm2 UV-B und-A und 14 mW/cm2 UV-C betrug. Über 1–6 Wochen wurden verschiedene Tiergruppen täglich 15–90 s exponiert. Die Reißkraft, die Reißfestigkeit und der Elastizitätsmodul zeigten nach mittleren Strahlendosen nach 1–2 Wochen eine Zunahme, jedoch nach hohen Strahlendosen und langdauernder Behandlung eine Abnahme. Die Dehnung beim Abriß war der empfindlichste Parameter insofern, als er in Abhängigkeit von Expositionszeit und Behandlungsdauer abnahm. Der Gehalt an unlöslichem Kollagen und Gesamtkollagen war nach langdauernder Behandlung vermindert und demnach mit den mechanischen Parametern korreliert. Der Elastin-Gehalt wurde nur gering beeinflußt und war somit mit den mechanischen Meßwerten nicht korreliert. In diesen Experimenten konnte ein günstiger Effekt einer kurzdauernden Behandlung mit niedrigen UV-Bestrahlungsdosen auf die mechanischen Eigenschaften der Haut gezeigt werden. Eine langdauernde Behandlung mit hohen Dosen von UV-B bewirkte jedoch ungünstige Effekte, wobei hauptsächlich die Dehnung beim Abriß, aber auch die Reißfestigkeit und der Elastizitätsmodul vermindert waren.
    Notes: Summary The effect of repeated UV-irradiation on mechanical and biochemical parameters was studied in skin of hairless mice. UV-A irradiation for a period of 1 h daily over 8 weeks caused only a slight increase in skin thickness and a decrease in ultimate strain. The changes induced by UV-B and C, however, were quite remarkable. Skin thickness was increased depending on the daily dose exposure time (15–90 s at an irradiation rate of 20 mW/cm2 UV-B and A and of 14 mW/cm2 UV-C) and the duration of treatment (1–6 weeks). Ultimated load, tensile strength and modulus of elasticity showed an increase following medium dosages after 1 and 2 weeks, however, a decrease after high dosages and longterm treatment. Ultimate strain was found to be the most sensitive parameter being decreased depending on exposure time and duration of treatment. Insoluble collagen and total collagen were decreased after long-term treatment thus being correlated with the mechanical parameters. The elastin content was only barely influenced and not correlated with the mechanical data, e.g. the modulus of elasticity. Thus, a favourable effect of short-term treatment with low doses of UV-irradiation of mechanical parameters of skin could be demonstrated. Long-term treatment with relatively high doses of UV-B, however, resulted in unfavourable effects, whereby first ultimate strain, then ultimate load, modulus of elasticity and tensile strength were decreased.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...