  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 79-90 
    ISSN: 0886-9383
    Keywords: PLS ; Three-way matrices ; Calibration ; Residual bilinearization ; Background correction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: When using hyphenated methods in analytical chemistry, the data obtained for each sample are given as a matrix. When a regression equation is set up between an unknown sample (a matrix) and a calibration set (a stack of matrices), the residual is a matrix R.The regression equation is usually solved by minimizing the sum of squares of R. If the sample contains some constituent not calibrated for, this approach is not valid. In this paper an algorithm is presented which partitions R into one matrix of low rank corresponding to the unknown constituents, and one random noise matrix to which the least squares restrictions are applied. Properties and possible applications of the algorithm are also discussed.In Part 2 of this work an example from HPLC with diode array detection is presented and the results are compared with generalized rank annihilation factor analysis (GRAFA).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 135-146 
    ISSN: 0886-9383
    Keywords: PLS ; Three-way matrices ; Calibration ; Residual bilinearization ; Background correction ; GRAFA ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The partial least squares-residual bilinearization (PLS-RBL) approach to background correction presented in Part 1 of this work is demonstrated with an example from HPLC with diode array detection. Data are also evaluated with generalized rank annihilation factor analysis (GRAFA) and results are compared.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource