Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 158 (1999), S. 589-591 
    ISSN: 1432-1076
    Keywords: Key words Air leak ; Nitric oxide ; Prematurity ; Respiratory distress syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Our aim was to identify factors predictive of death in preterm infants in whom inhaled nitric oxide was administered in response to poor oxygenation (oxygenation index ≥15). Of the 23 (median gestational age 28 weeks, range 24–36) infants consecutively so treated, 15 died. Non-survival was commoner in infants with air leaks (12 of 12, P 〈 0.002) and/or a change in their oxygenation index of less than 30% in response to inhaled nitric oxide administration (P 〈 0.05). Conclusion In preterm infants given inhaled nitric oxide because of poor oxygenation, a diagnosis of airleak and a lack of initial response are predictive of death.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 158 (1999), S. 796-799 
    ISSN: 1432-1076
    Keywords: Key words High frequency oscillation ; Respiratory distress syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The aim of this study was to compare gas exchange and volume delivery during high frequency oscillation at two frequently used inspiratory:expiratory (I:E) ratios: 1:2 and 1:1, other oscillatory settings being kept constant. A group of 13 infants with respiratory distress syndrome, median gestational age 28 weeks (range 23–36) and postnatal age 1 day (range 1–8) were studied. At the I:E ratio of 1:1 compared to 1:2 the median paCO2 was lower, P 〈 0.05 (30 mmHg, range 22–47 vs 34 mmHg, range 27–46) and the volume delivered higher, P 〈 0.01 (2.6 ml/kg, range 1.2–5.6 vs 2.0 ml/kg, range 1.0–3.9). There was no significant difference in oxygenation levels at the two I:E ratios. In a related in vitro study, changing the I:E ratio from 1:2 to 1:1 increased the mean airway pressure by a median of 8.6% (range 2.9–28.1%). Conclusion Routinely maintained longer expiratory than inspiratory times during high frequency oscillation should be discouraged.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...