Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: COPD ; High frequency jet ventilation ; Auto-PEEP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6±11 mmHg vs 80.8±12 mmHg; PaCO2 46.8±2.5 mmHg vs 47±2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as Δ over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9±3.8 cmH2O; auto-PEEPCMV 8.8±4.7 cmH2O; ΔFRCHFJV 0.56±0.19 l; ΔFRCCMV 0.54±0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Heat-moisture exchangers ; COPD ; Auto PEEP ; Controlled mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during “in vitro” studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with “new” HMEs and after 12 h of continuous use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1076
    Keywords: Corticosterone methyl oxidase type II ; Failure to thrive ; Salt wasting
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Corticosterone methyl oxidase type II (CMO II) deficiency is an uncommon cause of salt-wasting in infancy. We describe a boy who presented with recurrent dehydration and severe failure to thrive in the first 3 months of life, associated with mild hyponatraemia (serum Na+ 127–132 mEq/l) and hyperkalaemia (serum K+ 5.3–5.9 mEq/l). The diagnosis was suggested by an elevated plasma renin activity (PRA): serum aldosterone ratio, and subsequently confirmed by an elevated serum 18-hydroxycorticosterone: aldosterone ratio. Treatment with 9α-fluorohydroxycortisone normalized growth parameters and PRA levels. CMO II deficiency should be considered in infants with recurrent dehydration and failure to thrive, even when serum sodium and potassium levels are not strikingly abnormal.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...