Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Infrared spectrometry  (1)
  • Spinal fusion  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    Vibrational Spectroscopy 4 (1993), S. 365-371 
    ISSN: 0924-2031
    Schlagwort(e): Calcium oxalate ; Gas cell ; Infrared spectrometry ; Kerogen ; Pyrolysis
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European spine journal 6 (1997), S. 412-416 
    ISSN: 1432-0932
    Schlagwort(e): Outcome ; Spinal fusion ; Implant ; Rigid ; Semirigid
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Several biomechanical studies have evaluated the quality of fusion obtained with a rigid versus a semi-rigid pedicle screw implant. Some studies indicate that increased rigidity of the implant system results in an increased strength of the fusion mass. Other reports have underlined the risk of stress shielding due to rigid implant systems. Based on these findings some authors have recommended the use of a semi-rigid system. There are, however, few studies focusing on any possible difference in clinical outcome between the two different types of implant systems. Questionnaires were sent to 89 patients who had undergone primary spinal fusion with either a rigid or a semi-rigid pedicle-screw-based implant system. In every case the diagnosis was spondylolisthesis or degenerative lumbar disease. The questionnnaires were analysed using forward stepwise logistic regression analysis. Eighty (90%) of the questionnaires were returned. There was a mean follow-up of 4 years (range 2–8 years). It was not possible to demonstrate any difference in clinical outcome between patients undergoing lumbar fusion with a rigid implant system and those given a semi-rigid system. The overall patient satisfaction rate was 69%, with no difference between the two types of implant. No difference in clinical outcome between the two types of implant was found. Considering the fact that the primary goal of spinal fusion procedure is to obtain a solid fusion mass, biomechanical tests favour the used of a rigid pedicle screw system. This fact combined with the fact that early mobilisation is possible with rigid implants justifies the use of rigid implant systems, although no difference in clinical outcome could be demonstrated in this study.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...