    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 41-46 
    ISSN: 0935-6304
    Schlagwort(e): Chromatography ; Theory ; Chromatographic systems analysis ; Real plate number ; Fundamental interpretation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The real plate number concept is interpreted in terms of the fundamental properties of a chromatograph. It is shown that the linear relationship between the total peak width at half height, (b0.5)T, t, and k is only an approximation of the more general linear relationship between (b0.5)2T, t and (1 + k)2. In the case where the relationship between (b0.5)T, t and k approaches linearity, it is concluded, firstly, that b0 = a, i. e., b0 is a column property and independent of extra-column phenomena and, secondly, that nreal=ntheor. When the relationship becomes non-linear, b0 is determined partly by extra-column phenomena, but not in terms of a useful relationship. It is concluded that it is unnecessary to introduce the parameters a, b0 and nreal, since they all have counterparts in the established theory of chromatography. These counterparts prove to be equally useful in the practical analysis of chromatographic systems.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 456-460 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Capillary ; Theory ; Linearity between peak width and retention data ; Evaluation of GC equipment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The linearity of the relationship between σT,t2 and (1 + k)2 is studied with the view of using it for the evaluation of GC equipment. Based on appropriate analytical expressions it is concluded that in general this relationship is not linear and that practical procedures for column evaluation should be developed that take this non-linearity into account.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 172-176 
    ISSN: 0935-6304
    Schlagwort(e): Chromatography, LC and GC ; Capillary ; Theory ; Ultimate resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The expression for the resolution function, R, in terms of operating parameters for open tubular columns has been extended to include inlet contributions to the peak variance. Subsequent optimization has revealed the existence of optima in the column radius, the stationary phase thickness and the diffusion coefficient ratio in the stationary and mobile phases-in addition to the well-known optimum in the flow velocity. This implies that R at optimum becomes R=f(K)L0.6Vi-0.2, i.e. a function only of the column length, L, the inlet volume, Vi, and the concentration distribution coefficient, K. For given K, L and Vi all other parameters such as retention time and pressure drop can thus be directly computed. The information is finally consolidated in the form of contour diagrams. The text itself is cast in the form of a science fantasy.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 102-108 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Series-coupled columns with different stationary phases ; Independent temperature control of columns ; Constant mass flow rate ; Retention time expressions ; Theory ; Selectivity control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The technique of controlling chromatographic selectivity by the adjustment of column temperatures in systems of series-coupled columns is investigated by means of a general model incorporating the effects of temperature and mobile phase compressibility. In a previous article the performance of series-coupled columns was investigated under conditions of constant overall pressure drop. The present paper, on the other hand, considers systems in which a constant mass flow rate is maintained at all temperatures. The expressions derived for the effective partition coefficient and the retention time are compared with those of the previous paper. The numerical results for two-column systems exhibit the same major trends as those for constant pressure drop. It is shown that the effective partition coefficient is slightly dependent on the mass flow rate.
    Zusätzliches Material: 12 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 461-470 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Series-coupled columns equipped with different stationary phases ; Independent temperature control of columns ; Retention time expressions ; Theory ; Selectivity control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The promising technique of controlling chromatographic selectivity by the adjustment of individual column temperatures in systems of series-coupled columns is investigated by means of a general model incorporating the effects of temperature and mobile phase compressibility. Expressions are derived for the linear flow velocity, the effective partition coefficient and the retention time for a system of n columns assuming an ideal mobile phase gas, under conditions of constant overall pressure drop and neglect of the temperature dependence of the mobile phase viscosity. The results indicate the importance of thermodynamic parameters, relative to parameters influencing the linear flow velocity, in determining the effect of temperature on the chromatographic retention time. Numerical results are illustrated graphically for two-column systems which are discussed in greater detail. Switching of columns is also discussed and it is shown that even if thermodynamic contributions remain unchanged, non-thermodynamic contributions have a notice-able effect.
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 317-322 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Series-coupled columns with different stationary phases ; Independent temperature control of columns ; Constant mass flow and constant pressure drop ; Temperature dependence of viscosity coefficient ; Retention time expressions ; Theory ; Selectivity control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A previously established model of a system of series-coupled columns, incorporating the effects of temperature and mobile phase compressibility, is generalized to take the temperature dependence of the mobile phase viscosity coefficient into account. Expressions are reported for the linear flow velocity, the effective partition coefficient, and the retention time for both the case of constant mass flow rate and that of constant overall pressure drop. Numerical results indicate that the temperature dependence of the viscosity coefficient affects the retention time and pressure drop while the effective mass distribution coefficient remains essentially unchanged.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien