Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 649-651 
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography ; Cold on-column injection ; Sample split ; Three-way press-fit device ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 655-658 
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; Derivatized cyclodextrins ; Enantiomer separation ; Chromatographic performance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: This paper reports the chromatographic performance of columns coated with 2,3,6-trimethyl-α-, β-, and γ-cyclodextrins (2,3,6-TriMe-α,- β-, and γ-CD) and their derivatives 2,6-dimethyl-3-trifluoroacetyl-α-, β-, and γ-cyclodextrins (2,6-DiMe-3-TFA-α-, β-, and γ-CD), all six diluted in polysiloxane, for the separation of the enantiomers of volatile compounds.The influence of column length and film thickness on separation is reported. Phenomena related to reproducibility and consistency, over a period of time, of columns prepared with these CD derivatives are also discussed, and a possible solution to some drawbacks reported here is proposed.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography ; Enantiomer separation ; Amorphous cyclodextrin derivatives ; Diluting stationary phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: As a continuation of previous studies on the use of cyclodextrin derivatives (CD) for the separation of volatile compounds by capillary GC, the influence of diluting phases other than OV-1701 or OV-1701-OH has been investigated.2,6-Di-O-methyl-3-O-pentyl-β-cyclodextrin (2,6-DiMe-3-Pe-β-CD) was taken as the reference CD derivative, because of the large number of volatile racemates it is able to separate; OV-1701 or OV-1701-OH was chosen as the reference diluting phase.The performance of a column coated with a 0.15 μm film of 10 % 2,6-DiMe-3-Pe-β-CD in OV-1701 was compared with that of analogous columns coated with films of the same thickness containing the same percentage of the CD derivative diluted with stationary phases of different polarity, i.e. PS-086, PS-347.5, and OV-225. Resolution values and separation factors of thirty racemates were used to evaluate the effect of different diluting phases on column performance.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 155-159 
    ISSN: 0935-6304
    Schlagwort(e): Capillary gas chromatography ; Three-way press-fit device ; Cold on-column injection ; Solvent split ; Early solvent vapor exit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: In a previous paper we described the possibilities of cold on-column - sample split injection achieved by means of an inexpensive and simple three way press-fit device [1]. The same arrangement is proposed here for cold on-column - solvent split injection in which specific elimination of the solvent, without loss of any other sample components, is achieved by opening the splitting tube (or better, in this case, the early solvent vapor exit) during solvent elution, and then closing it during elution of the sample's other components.Discrimination between solvent and other sample components is achieved by means of a retention gap, a retaining precolumn, and an early vapor exit.The technique enables both selective enrichment of a sample, in order to record satisfactory mass and infrared spectra of minor components, and injection of large volumes (up to 100 μl) of dilute solutions which cannot be concentrated because of component volatility. Details of the assembly and tuning the system are given, together with some examples.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; Enantiomer separation ; Derivatized cyclodextrins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: This paper describes an evaluation of the chromatographic performance of columns coated with amorphous cyclodextrin (CD) derivatives, in particular 2,3,6-tripentyl-β-CD (2,3,6-TriPe-β-CD), 2,6-dipentyl-3-methyl-β-CD (2,6-DiPe-3-Me-β-CD), and 2,6-dimethyl-3-pentyl-β-CD (2,6-DiMe-3-Pe-β-CD), all diluted in polysiloxane (OV-1701 or OV-1701-OH), for the separation of the enantiomers of volatile compounds. 2,6-DiMe-3-Pe-β-CD in OV-1701 offers performance comparable with (or better than) that of the other two CDs, and without their drawbacks (inconsistency of results, as described previously).This article compares the separating ability of 2,6-DiMe-3-Pe-β-CD and 2,3,6-TriMe-β-CD, and describes the influence of the CD derivative to polysiloxane ratio, the minimum operating temperatures of the columns, and the reproducibility and consistency of performance of columns coated with the former CD derivative diluted in polysiloxane.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 0935-6304
    Schlagwort(e): Capillary GC ; Enantiomer separation ; Differently derivatized cyclodextrins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: In pre vious papers, 2,6-di-O-methyl-3-O-pentyl-β-cyclodextrin (CD) was demonstrated to be successful in separating volatile compounds, while avoiding the drawbacks of 2,3,6-tri-O-methyl-O-methyl-β-CD in terms of column stability and operating temperature.Since a CD chiral selector of universal use has not yet been found, and at least two (or more) columns coated with different CD derivatives are therefore necessary for routine work, the performance of 2,6-di-O-methyl-3-O-pentyl-γ-CD, 2,6-di-O-methyl-3-O-(4-oxopentyl)-γ-CD, 2,6-di-O-pentyl-3-O-(4-oxo-pentyl)-β-CD, and 2,6-di-O-pentyl-3-O-(-4-oxo-pentyl)-γ-CD diluted in polysiloxanes for the separation of volatile compounds in aromas and essential oils will be illustrated; each column coated with each of the newly synthesized CD derivatives was evaluated by analyzing more than 150 different recemates with different structures.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...