Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gas chromatography-mass spectrometry ; Water analysis ; Triazine herbicides ; Chemical ionization mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Mass spectra of 12 triazines were obtained by electron impact (EI), positive-ion chemical ionization (PCI) and negative-ion chemical ionization (NCI) using methane and isobutane as reagent gases. EI mass spectrometry is more sensitive than PCI and NCI, although the chemical ionization modes increase selectivity markedly. A pre-column packed with polymer stationary phase was employed to preconcentrate surface and drinking water samples. After desorption of the analytes with ethyl acetate, an aliquot was injected directly into the GC-MS system. Atrazine and simizine were found in these samples at 10–80 ppt levels. The limits of detection for both herbicides were below 10 ppt in drinking water.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Trace enrichment ; Membrane extraction disks ; Triazine herbicides ; 2,3,4-Trichlorophenol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Membrane extraction disks have been recently introduced for the solid-phase extraction of organic compounds from aqueous samples. The material consists of alkyl-modified silica particles enmeshed in an inert PTEE matrix. Aqueous samples containing polar pesticides and herbicides, are preconcentrated on-line from acidic solutions on membrane extraction disks containing immobilized octadecyl-modified silica and analyzed with an isocratic liquid chromatographic system using PLRP-S as the stationary phase and aqueous acetonitrile mixtures (pH 3) as the eluent. Data on the lifetime and the dimensions of the preconcentration disks, and the efficiency and the repeatability of the procedure are reported. For 10 ml samples, the detection limits of the analytes atrazine, simazine and 2,3,4-trichlorophenol in tap water are 0.1–1 ppb.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...