Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 7 (1993), S. 544-549 
    ISSN: 1432-2218
    Keywords: Intracorporeal ultrasonography ; Laparoscopic ultrasonography ; Ultrasound examination ; Ultrasound technique ; Laparoscopic cholecystectomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Intracorporeal ultrasonography was used as a new method to examine the bile ducts during laparoscopic cholecystectomy. A prototype rigid 7.5-MHz ultrasound probe, 10 mm in diameter and 50 cm in length, was introduced during 25 laparoscopic cholecystectomies. A dual scanning technique was developed for complete examination of the bile duct. This entailed transverse scanning via the subxyphoid trocar and longitudinal scanning via the umbilical trocar. The intrahepatic ducts were also visualized by placing the probe on the liver surface. Color Doppler imaging was useful to quickly distinguish the duct from vascular structures. Laparoscopic ultrasonography clearly delineated the bile ducts in all operations except one. The time required for imaging was significantly shorter for ultrasonography than for cholangiography. Our preliminary experience demonstrates that a complete examination of the bile ducts can be performed with intracorporeal ultrasonography in a relatively short period of time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 684-689 
    ISSN: 1432-2218
    Keywords: Laparoscopic ultrasound ; Intraoperative ultrasound ; Ultrasound technique ; Liver ; Pancreas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Since the introduction of a recent laparoscopic ultrasound (LU), the value of this modality in examining the liver and pancreas has been reported. However, a precise scanning technique of LU has not previously been described. Based on our experience with intraoperative ultrasound during laparotomy, we have developed a technique for complete examination of the entire organs using a rigid LU probe. A 7.5-MHz rigid probe, 10 mm in diameter, was employed. The scanning was performed through three trocar ports: right subcostal, subxiphoid, and umbilical. For the liver, the subcostal scanning provided fundamental transverse views. The subxiphoid and umbilical scanning delineated the areas unable to be imaged by the subcostal scanning. For the pancreas, the subcostal and umbilical scanning demonstrated longitudinal and transverse views, respectively. The subxiphoid scanning enhanced examination of the pancreatic head. Three basic probe maneuvers (advancement-withdrawal, lateral movement, and rotation) and various scanning techniques (contact, probe-standoff, and compression scanning) should be utilized appropriately. With a rigid probe, complete LU examination of the liver and pancreas is possible using these techniques. We believe the present scanning method will help more surgeons learn LU.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 23 (1977), S. 948-951 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A class of dynamic model approximation techniques based on a frequency domain Taylor series expansion is presented. These methods yield low-order models and are analytical rather than computational in nature; that is, one can retain important parameters (which may be time varying) from the original model in functional form in the low-order model. This feature is very attractive for on-line updating of the simplified model and subsequent control of the process. An example for a tenth-order original model has shown that the analytical low-order models provide excellent approximations to the step response of the original system.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 22 (1976), S. 894-904 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A new tracer technique is reported for the determination of liquid-solid contacting efficiency and liquid holdup in trickle beds packed with small alumina particles. Holdup was a function of liquid mass velocity for both porous and nonporous packing. Contacting efficiency remained uniform at a level of 65%.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 22 (1976), S. 953-956 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...