Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 69 (1996), S. 45-52 
    ISSN: 1432-1246
    Keywords: Key words Vibratory sensation ; Vibration exposure ; Threshold shift ; Temporary threshold shift ; Gripping force
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract ⋅Objective This study examines the effect of the force with which a vibrating handle is gripped on the temporary threshold shift of vibratory sensation (TTSv) induced by hand-arm vibration. ⋅  Methods Six healthy subjects gripped a handle vibrating with a 1/3 octave-band vibration, with a central frequency of 200 Hz and an intensity of 39.2 m/s2. Exposure was for 1 min and 10 min, respectively. Gripping forces for the 1-min exposure were 5 N, 10 N, 40 N and 80 N, respectively, with 0 N push-pull force. Gripping forces for the 10-min exposure were the same as for the 1-min exposure, but omitting 80 N. The vibratory sensation threshold at 125 Hz was measured before and after exposure of an exposed fingertip to vibration. The differences measured determine TTS v,t at time t. TTS v,t determines TTSv,0, that is, the temporary threshold shift of vibratory sensation immediately after exposure to vibration according to the estimate made on the basis of the preceding study. The same experimental conditions were repeated 3 times on different days in a soundproof and thermoregulated room. ⋅  Results Our findings show that TTSv increases significantly with increasing gripping force. We also determined the quantitative relationships between TTSv,0 and gripping force as described by the equation where k f and c f are constants and F is gripping force. ⋅  Conclusion This study revealed the importance of ergonomic design in reducing the force with which a vibrating handle is gripped to prevent an adverse effect of local vibration. The equation devised may help in the quantitative assessment of the effect of reduced gripping force.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 63 (1992), S. 531-535 
    ISSN: 1432-1246
    Keywords: Human skin ; Temperature sensation ; Vibration exposure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The temporary threshold shift of temperature sensation due to vibration exposure was studied to clarify the significance of frequency and acceleration on it. The discrete frequencies of the vibrations tested were 32, 63, 125, 250 and 500 Hz, and the accelerations were at the level of 2, 4, 8 and 16 g. The threshold shift of warm sensation (TTSw) was markedly, but that of cool sensation was small and not significantly different from the control value. TTSw increased with a rise in the level of acceleration and was largest at 125 Hz among the frequencies examined. The most effective frequency among the vibrations tested for warm sensation was inferred to be lower than that for vibratory sensation. After exposure, TTSw or the increment of the neutral zone decayed exponentially but bounced slightly in the later period. These patterns of TTSw are similar to those of the vibration-induced TTS of vibratory sensation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...