Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 1 (1975), S. 129-136 
    ISSN: 1432-1238
    Keywords: Microembolism ; arthroplasty ; lung function ; Xe133 radiospirometry ; IPPB (Intermittent positive pressure breathing) ; epidural anesthesia ; pulmonary blood volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary With a Xenon133 radiospirometric technique the regional lung function was evaluated before and after prosthetic hip arthroplasty performed in the lateral decubitus position with either respirator-controlled neuroleptic anesthesia or epidural anesthesia with spontaneous breathing. Regional lung function measured in a supine position 1, 20 and 72-96 hours postoperatively revealed a reduction of the perfusion, ventilation and volume of ventilated alveoli on the dependant lung. The reduction was most pronounced immediately postoperatively, especially following respirator-controlled anesthesia. There was also an increase of pulmonary blood volume and a decrease of total lung volume in this group. The changes of lung function are probably caused by congestive atelectasis, secondary to impaired ventilation of the dependent lung. Peroperatively induced microembolism might have potentiated the effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...