Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Chemical Engineering  (2)
  • critical molecular weight  (1)
Materialart
Erscheinungszeitraum
Schlagwörter
  • 1
    Digitale Medien
    Digitale Medien
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 34 (1994), S. 109-115 
    ISSN: 0032-3888
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: Slow crack growth was measured in the perpendicular and parallel directions relative to the extrusion direction of the pipe. For five pipes from different manufacturers, the anisotropy factor, the lifetime to fracture in the perpendicular direction divided by lifetime in the parallel direction, varied from 1.2 to 4.7 for complete fracture and 1.4 to 4.0 for crack initiation. The degree of molecular orientation was determined by measuring the shrinkage that occured when a pipe specimen was heated near its melting point. The amount of shrinkage correlated with the anisotropy factor for slow crack growth. The shape change after shrinkage was related to the flow pattern of the resin during extrusion and the cooling rate after extrusion.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 30 (1990), S. 1175-1179 
    ISSN: 0032-3888
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The time for brittle failure by slow crack growth for 22 polyethylene copolymers was measured in Igepal and air. The notched tensile tests were conducted in Igepal and air at 50°C and 4.2 MPa and in air at 80°C and 2.4 MPa. For failure times less than 103 min, the difference between the Igepal and air environments was not measurable. As the failure time increased beyond 103 min, the ratio of failure in air compared to that in Igepal increased so that for the very highest failure times of 5 × 105 to 108 min in air, the failure time in Igepal was reduced by 25 - 50 times. The correlation between the Igepal and air tests was generally good with respect to all types of polyethylene. However, a separation of the polyethylenes with respect to their comonomer, butene, hexene, or octene improved the correlation. The resistance to slow crack growth of all the current commercial polyethylene copolymers can be assessed by a notched tensile test in Igepal in about a week or less.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 34 (1996), S. 1809-1813 
    ISSN: 0887-6266
    Schlagwort(e): slow crack growth ; polyethylene ; critical molecular weight ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: An ethylene-hexene copolymer was fractionated into five fractions and the density of short-chain branches was measured for each fraction. The slow crack growth behavior was measured on each fraction by sandwiching the small amount of fractionated resin of about 0.2 g between polyethylene grips. The resistance to slow crack growth was negligible for the three fractions whose Mw was less than 1.5 × 105. For the fourth fraction with Mw greater than 1.5 × 105, the resistance to slow crack growth was very high, being greater than that for the whole resin even though its density of short-chain branches was less than that of the whole resin. It is concluded that a molecular weight greater than 1.5 × 105 is required to create the number of tie molecules that is necessary to produce a high resistance to slow crack growth in this particular copolymer. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...