Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 51 (1996), S. 15-22 
    ISSN: 0006-3592
    Keywords: preparative separation ; continuous ; free-flow zone electrophoresis ; electrophoretic mobility ; net charge ; enzymes ; proteins ; crude extract ; cell debris ; Candida boidinii ; Escherichia coli ; formate dehydrogenase ; formaldehyde dehydrogenase ; methanol oxidase ; β-galactosidase ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Continuous, single-step, state-of-the-art preparative separations of enzymes from microorganism crude extracts by free-flow zone electrophoresis are presented. In the first example, the enzymes formate dehydrogenase, formaldehyde dehydrogenase, and methanol oxidase were continuously separated from Candida boidinii crude extract. Yields of 85% to 95% and purification factors between 3 and 7 were obtained along with a simultaneous separation of the finer cell debris from the enzymes. Using multiple injections of sample, a throughput of 46.2 mg protein/h was recorded. In the second example, a fivefold purification of β-galactosidase from Escherichia coli was achieved along with complete, simultaneous cell debris separation from the enzyme. The yield of the enzyme was greater than 90%. The preparative free-flow zone electrophoresis experiments were run continuously for a period of 12 h and the separations were found to be stable; i.e., the enzymes and the cell debris eluted at their respective fraction numbers during the entire period. In both examples, choice of the type of buffer played a critical role and had to be investigated and optimized experimentally. Scale-up aspects of the separations are also discussed. Recently, by comparison of free-flow zone electrophoresis with ion-exchange chromatography, we have presented evidence that free-flow electrophoresis separations are governed by net surface charge (S. Nath et al., Biotechnol. Bioeng. 1993, 42: 829-835). Here, we offer further confirmation of this evidence by comparison of preparative free-flow zone electrophoresis experiments at various pHs on a mixture of two model proteins with analytical electrophoretic titration curves of the proteins. We are thus in a position to predict separations in free-flow zone electrophoresis. © 1996 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...