Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 4 (1984), S. 137-149 
    ISSN: 0886-1544
    Keywords: anti-fluorescein ; fluorescent analog cytochemistry ; molecular cytochemistry ; microinjection ; actin ; acetamidofluorescein-actin ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Fluorescent analogs of cellular components are finding increasing use in the field of cell biology. The power of this technique can be augmented by the use of antibodies specific for the fluorophore to visualize selectively the fluorescent analog at the electron microscope level. Rabbit antibodies specific for fluorescein were elicited and purified according to published methods (Lopatin and Voss [1971]: Biochemistry 10:208). Immune sera and IgG formed precipitin lines with fluorescein-labeled proteins in Ouchterlony immunodiffusion assays, and significantly quenched the fluorescence of fluorescein-labeled proteins. Immune IgG and Fab fragments decorated fluorescein-labeled actin, but not unlabeled actin, in negative-stained preparations. Anti-fluorescein IgG was used for immunofluorescent localization of fluorescein-labeled actin following microinjection of the fluorescent analog into living cells. This approach was extended to the immunoelectron microscopic localization of the injected analog at the subcellular level by the use of an electron-dense marker coupled to goat anti-rabbit IgG. Many other fluorescent probes also can be used as haptens for production of antibodies. Therefore, a general method for localizing fluorescently labeled molecules at the electron microscopic level is now available. Several other applications of anti-fluorescein antibody in studies involving fluorescent analogs are also suggested.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 4 (1984), S. 197-213 
    ISSN: 0886-1544
    Keywords: gelation ; actin ; filamin ; cytoplasm ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: We have compared the meniscus depletion assay and falling ball viscometry, two means of assessing the extent of gelation in actin-based systems using mixtures of actin and the actin-binding protein filamin. We examined the effect of varying the concentrations of actin and filamin in both assays. The interaction of actin and filamin was detected only above a threshold concentration of filamin. This threshold concentration was lower for falling ball viscometry than for the meniscus depletion assay at equal actin concentrations. At constant concentrations of filamin, an increase in actin concentration caused an increase in apparent viscosity measured by the falling ball assay, but a decrease in sedimentability detected by the meniscus depletion assay. The rate of sedimentation of actin was dependent on the molar ratio of actin to filamin. At each molar ratio, the sedimentation of actin was not dependent on the specific concentrations of actin and filamin used. The apparent viscosity was dependent on both the molar ratio and the specific concentrations of actin and filamin. To relate the present results to earlier studies, we examined mixtures of actin and filamin using a macroscopic assay of gelation (tube tipping assay), and polarized light microscopy. The effect of increasing filamin concentration in the four assays was compared at three actin concentrations. Mixtures of actin and filamin whose apparent viscosities were low enough to be estimated by falling ball viscometry were optically isotropic fluids that flowed out of inverted test tubes. Mixtures of actin and filamin in the range of sensitivity of the meniscus depletion assay were either viscous fluids or gels, and were either optically isotropic or anisotropic. Thus, the four assays provide different estimates of gelation. Both the meniscus depletion assay and falling ball viscometry can be used to determine relative gelation activity, but neither can be used as a quantitative assay of gelation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...