Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 20 (1999), S. 733-742 
    ISSN: 1572-9567
    Keywords: calorimetry ; diffusivity ; emissivity, heat capacity ; radiant exchange ; simultaneous measurement ; thermal conductivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Thermal radiation calorimetry has been applied to measure the thermal diffusivity of a solid specimen, along with simultaneous measurements of specific heat capacity and thermal conductivity. In this calorimeter, a disk-shaped solid specimen whose surfaces are blackened is heated and cooled slowly on one face by irradiation in a vacuum chamber. A quasi-steady-state approximation in which a linear temperature gradient within the specimen was assumed is considered in the analysis. The validity of this approximation was confirmed by the results of computer simulation based on the control-volume method. Measurements of Pyroceram 9606 and Pyrex 7740 by use of thermocouples in the temperature range between 250 and 400°C gave values consistent with those obtained by previous authors, within experimental error, for all three thermophysical properties.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 21 (2000), S. 927-940 
    ISSN: 1572-9567
    Keywords: calorimetry ; emittance ; fused silica ; hemispherical total emissivity ; refractive index ; spectral emissivity ; thermal conductivity ; virtual mode ; Vycor glass
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An attempt to derive the hemispherical total emissivity from the normal emission spectrum is proposed for Vycor and fused silica glasses. The normal emission spectrum from a clear surface has been measured at steady state in the temperature range from 400 to 750 K. The sample is heated on one metal-backed face by thermal radiation from a heater. Temperatures inside the sample were monitored by thermocouples at two points near the surfaces. Evaluation of the hemispherical total emissivity from the normal emission spectrum is determined by means of Kramers–Krönig analysis and virtual mode equations. Assuming a linear temperature distribution within the sample, the thermal conductivities of silicate glasses were obtained at elevated temperatures. The results are comparable with those obtained by previous investigators. The effect of radiation heat transfer in a sample is also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...