Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (2)
  • PACS. 61.16.Ch Scanning probe microscopy: scanning tunneling, atomic force, scanning optical, magnetic force, etc. - 68.55.-a Thin film structure and morphology  (1)
  • dilated cardio-myopathy  (1)
Materialart
Erscheinungszeitraum
  • 1995-1999  (2)
Jahr
Schlagwörter
  • 1
    ISSN: 1435-1803
    Schlagwort(e): Frank-Starling ; mechanism ; heart failure ; normal donor hearts ; dilated cardio-myopathy ; heart transplantation ; skinned fibres
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The Frank-Starling-mechanism (FSM) was analyzed in isolated intact and skinned human left ventricular myocardium obtained from 11 heart transplantations (normal donor hearts (NDH), n=8; dilated cardiomyopathy (DCM), n=11). The new technique to utilize muscle strips from normal donor hearts which were actually implanted is described in detail. Methods I) In electrically stimulated left ventricular trabeculae (37°C, oxygenated Krebs-Henseleit solution, supramaximal, electrical stimulation, frequency 1 Hz) force development was analyzed as a function of muscle length (NDH=8; DCM=11). II) In an additional series left ventricular myocardium was demembranized (“skinned”) by Triton-X-100. At different sarcomere lengths and calcium concentrations corresponding to pCa values of 4.3, 5.5, and 8.0 force development was measured (DCM=11; NDH=9). Results I) Developed force increased up to an optimum as a function of muscle length in intact NDH- and DCM-myocardium. However, the relative increment of developed force after any length step was smaller in DCM than in NDH. Near “Lmax” (muscle length associated with maximum developed force) passive resting tension was considerably elevated in DCM, indicating significantly incresed diastolic stiffness II) In skinned left ventricular DCM- and NDH-myocardium developed force depended on sarcomere length with an optimum near 2.2 μm. However, a reduction of activator calcium concentration from pCa 4.3 to pCa 5.5 produces a smaller percent decline in force at short sarcomere lengths in DCM than it does in NDH. Conclusion the present study shows that except for diastolic stiffness and a smaller relative force increment after any, length step in DCM the Frank Starling mechanism is still present in isolated human left ventricular DCM-as in NDH-myocardium. The current study does not allow to decide whether in skinned myocardium the smaller percent decline in force after reduction of activator calcium concentrations in DCM is caused by an increased calcium sensitivity at short sarcomere lengths or decreased sensitivity at long sarcomere lengths.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    The European physical journal 4 (1998), S. 267-268 
    ISSN: 1434-6036
    Schlagwort(e): PACS. 61.16.Ch Scanning probe microscopy: scanning tunneling, atomic force, scanning optical, magnetic force, etc. - 68.55.-a Thin film structure and morphology
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract: We report molecularly resolved dynamic AFM-measurements of a monolayer of perylene-3,4,9,10-tetracarboxylic-3,4,9,10-dianhydride (PTCDA) epitaxially grown on Ag(110). Preparation and experiments were performed under UHV conditions. The frequency-modulation AFM technique was applied.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...