Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-2622
    Keywords: diabetic retinopathy ; standing potential ; hyperosmolarity response ; Diamox response ; light peak/dark trough (L/D) ratio ; electro-oculogram (EOG)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The hyperosmolarity response, a drug-induced response from the retinal pigment epithelium, was recorded in diabetic retinopathy. The hyperosmolarity response was occasionally abnormal at the pre-retinopathic stage and at the first stage of retinopathy by Scott classification. The response was frequently abnormal at the second and third stages of retinopathy. The hyperosmolarity response is useful for early diagnosis of pigment epitheliopathy in diabetes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2622
    Keywords: retinal pigment epithelium (RPE) ; ocular standing potential ; hyperosmolarity response ; electro-oculogram (EOG)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The standing potential of the eye is decreased by intravenous administration of hypertonic solutions. This hyperosmolarity-induced response has been recorded in normal subjects by the use of electro-oculography (EOG) in the dark. An intravenous administration of Fructmanit® (1.4 × 103 mOsmol) (150 ∼ 500ml, 2.37 ∼ 9.70ml/kg, 0.08 ∼ 0.36 ml/kg/min) was used to evoke the hyperosmolarity response. The amplitude of the response was expressed in percentage, V0 − Vmin/V0 × 100, where V0 is the base value of the EOG before administration of the hypertonic solution and Vmin is a minimum EOG amplitude after administration. The distribution of the amplitude of the hyperosmolarity response was approximated by the normal distribution in normal subjects. The minimum, the maximum, the mean and the standard deviation of the amplitude of the hyperosmolarity response were respectively 34.2%, 52.3%, 42.6% and 4.6% in normal subjects. The normal range of the hyperosmolarity response would be 33.4 ∼ 51.8% (M ± 2SD). The hyperosmolarity response, which originates mainly in the retinal pigment epithelium, is a useful new quantitative and specific test of the activity of the retinal pigment epithelium in clinical practice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-2622
    Keywords: retinal detachment ; standing potential ; hyperosmolarity response ; light peak/dark trough (L/D) ratio ; electro-oculogram (EOG)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The hyperosmolarity response of the ocular standing potential was recorded in unilateral rhegmatogenous retinal detachment (8 eyes) and in the fellow ‘healthy’ eye (8 eyes). The hyperosmolarity response was greatly suppressed (M-4 SD: M and SD indicate respectively the mean and the standard deviation in normal subjects) in all affected eyes (p 〈 0.005), and slightly abnormal in 2 fellow eyes. The L/D ratio was normal in 2 affected eyes and in all fellow eyes. The hyperosmolarity response in the affected eyes was still greatly suppressed 14 months after successful surgical treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗