Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0899-0042
    Keywords: stereoselective excretion ; enantioselective ; chromatography ; assay validation ; hydroxychloroquine metabolism ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sequential achiral-chiral high-performance liquid chromatographic system has been developed for the quantitation in urine of the enantiomers of hydroxychloroquine (HCQ), and of its 3 major metabolites, desethylhydroxychloroquine (DHCQ), desethylchloroquine (DCQ), and bisdesethylchloroquine (BDCQ). HCQ and its metabolites were separated and quantified on a cyano-bonded phase, and the enantiomeric ratios were determined using a Chiral-AGP chiral stationary phase. The assay validation and application of this method to a preliminary study in a human volunteer are presented. In this subject, the initial 0-4 h urine contained the 2 HCQ enantiomers in a ratio of (+)-HCQ:(-)-HCQ of 3:2; by the 2,064 h of the study, this ratio had reversed to (+)-HCQ:(-)-HCQ of 3:7. © 1993 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Chirality 5 (1993), S. 84-90 
    ISSN: 0899-0042
    Keywords: in vitro dissolution ; enantioselective ; enantiomers ; bioequivalency ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The stereoselectivity of the in vitro dissolution of two commercially available sustained release formulations of rac-verapamil (rac-VER) has been investigated. The studies were carried out using a single-tablet continuous-flow apparatus and the concentrations of R- and S-VER released from the formulations were measured using enantioselective chromatography on a high performance liquid chromatography (HPLC) chiral stationary phase containing immobilized α1-acid glycoprotein (Chiral AGP-column). The data from this study demonstrates that the two formulations have different dissolution profiles and that the amount of drug dissolved was highly dependent on pH. In addition, between pH 3 and 8, the total cumulative amount of R-VER released was greater than the amount of S-VER and a statistically significant difference (P 〈 0.01) was detected at pH 6. The results of this study indicate that bioavailability and bioequivalency studies should consider the possibility of enantioselective dissolution when racemic compounds are present in the formulations. © 1993 Wiley-Liss, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...