Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-904X
    Keywords: iontophoresis ; Nernst-Planck equation ; percutaneous penetration ; skin resistance ; skin capacitance ; peptide DGAVP ; human skin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract This study deals with effects of electrical (current density, frequency and duty cycle) and chemical (buffer pH and ionic strength) conditions on the flux of the octapeptide, 9-desglycinamide, 8-arginine-vasopressin (DGAVP), through dermatomed human skin. A pulsed constant current was applied during iontophoresis. The anode faced the anatomical surface of the skin samples inside the diffusion cells. The resistive and capacitative components of the equivalent electrical circuit of human skin could be calculated by fitting the voltage response to a bi-exponential equation. The skin resistance prior to iontophoresis varied between 20 and 60 k Ω.cm2. During iontophoresis a decrease of skin resistance and an increase of the series capacitances was observed, which were most pronounced during the first hour of iontophoresis; thereafter both quantities gradually levelled off to an apparent steady state value. The reduction of the resistance during iontophoresis increased non-linearly with increasing current density between 0.013–0.64 mA.cm−2. The steady state resistance and capacitances did not vary significantly with frequency and duty cycle of the current pulse. There was no pH dependence of skin resistance at steady state. Between pH 4 and 10, the steady state peptide flux had a bell-shaped pH-dependence with a maximum of 0.17 nmol.cm−2.h−1 at pH 7.4, which is close to the I.E.P. of the peptide. Lowering the ionic strength from 0.15 to 0.015 M NaCl increased the steady state flux at pH 5 and pH 8 by a factor 5 to 0.28 ± 0.21 and 0.48 ± 0.37 nmol.cm−2.h−1, respectively. Together these observations suggested that DGAVP is transported predominately by volume flow. At pH 6, at which 65% of the peptide carried a net single positive charge, the steady state flux increased with increasing current density (0.013–0.64 mA.cm−2) from 0.11 ± 0.03 to 0.19 ± 0.04 nmol.cm−2.h−1. Skin permeability during passive diffusion preceding iontophoresis at pH 6.0 was 2.9 ± 0.6 * 10−7 cm.h−7. In accordance with theoretical predictions based on the Nernst-Planck equation, to which a volume flow term was added, the flux was proportional to the mean voltage across the skin between 0.013 and 0.32 mA.cm−2.h−1. Variation of frequency or duty cycle did not result in significantly different peptide transport rates. From these studies it is concluded that DGAVP can be transported iontophoretically through human skin. The pH- and ionic strength-dependence of the iontophoretic peptide flux suggests that transport of DGAVP mainly occurs by volume flow. Furthermore, the flux of DGAVP appears to be controlled by the applied voltage rather than by the current density, as predicted by the Nernst-Planck equation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...