Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Veterinary research communications 22 (1998), S. 193-201 
    ISSN: 1573-7446
    Schlagwort(e): diagnosis ; dog ; ELISA ; faeces ; latex agglutination ; occult blood ; serology
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Faecal haemoglobin (Hb) concentrations in apparently healthy experimental Beagle dogs and in dogs of various breeds kept in private households or at breeders were measured by reversed passive latex agglutination (RPLA) and enzyme-linked immunosorbent assay (ELISA) in an effort to define the physiological concentrations of faecal Hb in the dog. In 88% (53) of 60 experimental Beagle dogs (30 males and 30 females), the RPLA titres were 1:2 and 1:8 and the faecal Hb concentrations ranged from 40.0 to 431.5 (mean 184.1±92.6) μg/g faeces by ELISA. No significant difference was found in Hb levels or RPLA titres between males and females. Seven dogs (12%) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. In 84% (45) of the 53 dogs kept in private households or at breeders, the RPLA titres were 〉1:1 to 1:8 and the faecal Hb concentrations ranged from 7.1 to 456.7 (mean 137.5±128.7) μg/g faeces in ELISA. Eight of these dogs (15.1% of 53 dogs) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. There were no significant differences between the Beagles and dogs kept in private households or at breeders. In conclusion, in 98 (86.7% of 113) dogs the physiological concentrations of RPLA titres were 〉1:1 to 1:8 and the faecal Hb concentrations were 143.5–185.1 μg/g (95% confidence level). Approximately 13.3% of apparently healthy dogs had higher faecal Hb concentrations, suggesting the presence of subclinical haemorrhages. Four dogs suffering from colorectal cancer also had high faecal Hb concentrations.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1573-2622
    Schlagwort(e): retinal detachment ; standing potential ; hyperosmolarity response ; light peak/dark trough (L/D) ratio ; electro-oculogram (EOG)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The hyperosmolarity response of the ocular standing potential was recorded in unilateral rhegmatogenous retinal detachment (8 eyes) and in the fellow ‘healthy’ eye (8 eyes). The hyperosmolarity response was greatly suppressed (M-4 SD: M and SD indicate respectively the mean and the standard deviation in normal subjects) in all affected eyes (p 〈 0.005), and slightly abnormal in 2 fellow eyes. The L/D ratio was normal in 2 affected eyes and in all fellow eyes. The hyperosmolarity response in the affected eyes was still greatly suppressed 14 months after successful surgical treatment.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1573-2622
    Schlagwort(e): retinal pigment epithelium (RPE) ; standing potential ; hyperosmolarity response ; retinitis pigmentosa ; central and pericentral retinitis pigmentosa ; pigmented paravenous retinochoroidal atrophy ; fundus albipunctatus ; Stargardt's disease ; fundus flavimaculatus ; light peak/dark trough (L/D) ratio ; Diamox response ; electro-oculogram(EOG)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The hyperosmolarity response of the standing potential was recorded in retinitis pigmentosa (20 eyes), central (pericentral) retinitis pigmentosa (4 eyes), pigmented paravenous retinochoroidal atrophy (2 eyes), fundus albipunctatus (8 eyes), and Stargardt's disease (or fundus flavimaculatus) (14 eyes). The light peak/dark trough ratio (the L/D ratio) and the Diamox response were also determined. The hyperosmolarity response was greatly suppressed (less than M-4SD; M and SD indicate respectively the mean and the standard deviation in normal control subjects) in all examined eyes with retinitis pigmentosa (20 eyes) including retinitis pigmentosa sine pigmento (8 eyes), central (pericentral) retinitis pigmentosa (4 eyes), and pigmented paravenous retinochoroidal atrophy (2 eyes). The L/D ratio was larger than 1.26 (M-2.5 SD) in the half of the eyes with the above-described diseases. The hyperosmolarity response was abnormal (less than M-2 SD) in 4 of 8 eyes with fundus albipunctatus. The L/D ratio was normal in all 8 eyes. The hyperosmolarity response was abnormal (less than M-2 SD) in all 14 eyes with Stargardt's disease or fundus flavimaculatus. The L/D ratio was abnormal in 5 of these 14 eyes. The hyperosmolarity response was more frequently abnormal than the L/D ratio in the chorioretinal dystrophies mentioned above, and hence is useful particularly for early diagnosis of these disorders.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1573-2622
    Schlagwort(e): diabetic retinopathy ; standing potential ; hyperosmolarity response ; Diamox response ; light peak/dark trough (L/D) ratio ; electro-oculogram (EOG)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The hyperosmolarity response, a drug-induced response from the retinal pigment epithelium, was recorded in diabetic retinopathy. The hyperosmolarity response was occasionally abnormal at the pre-retinopathic stage and at the first stage of retinopathy by Scott classification. The response was frequently abnormal at the second and third stages of retinopathy. The hyperosmolarity response is useful for early diagnosis of pigment epitheliopathy in diabetes.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1573-2622
    Schlagwort(e): retinal pigment epithelium (RPE) ; ocular standing potential ; hyperosmolarity response ; electro-oculogram (EOG)
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The standing potential of the eye is decreased by intravenous administration of hypertonic solutions. This hyperosmolarity-induced response has been recorded in normal subjects by the use of electro-oculography (EOG) in the dark. An intravenous administration of Fructmanit® (1.4 × 103 mOsmol) (150 ∼ 500ml, 2.37 ∼ 9.70ml/kg, 0.08 ∼ 0.36 ml/kg/min) was used to evoke the hyperosmolarity response. The amplitude of the response was expressed in percentage, V0 − Vmin/V0 × 100, where V0 is the base value of the EOG before administration of the hypertonic solution and Vmin is a minimum EOG amplitude after administration. The distribution of the amplitude of the hyperosmolarity response was approximated by the normal distribution in normal subjects. The minimum, the maximum, the mean and the standard deviation of the amplitude of the hyperosmolarity response were respectively 34.2%, 52.3%, 42.6% and 4.6% in normal subjects. The normal range of the hyperosmolarity response would be 33.4 ∼ 51.8% (M ± 2SD). The hyperosmolarity response, which originates mainly in the retinal pigment epithelium, is a useful new quantitative and specific test of the activity of the retinal pigment epithelium in clinical practice.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 1573-7446
    Schlagwort(e): agglutination ; capillary RPLA ; C-reactive protein ; ELISA ; latex ; single radial immunodiffusion
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A capillary reversed passive latex agglutination test (capillary RPLA) was developed which allows quantification of serum C-reactive protein (CRP) within approximately 15 min. The logarithmic regression line (calibration curve) obtained after measuring each CRP concentration three times in twofold dilutions of a standard canine serum containing 222 μg/ml of CRP was y=6.394+0.030x (r=0.995). Capillary RPLA permitted quantification of CRP in the range 6.9–222 μg/ml. The coefficients of variation ranged from 10.28% to 12.40%. The recovery rates (percentage recovery) of CRP by capillary RPLA were within the range 87% to 106%. On measuring the CRP concentrations in sera from 78 dogs by capillary RPLA, single radial immunodiffusion (SRID) and enzyme-linked immunosorbent assay (ELISA), close correlations were demonstrated between SRID and capillary RPLA (y=7.250+1.109x, r=0.978), between SRID and ELISA (y=3.042+1.059x, r=0.967), and between capillary RPLA and ELISA (y=1.778+0.929x, r=0.962). Capillary RPLA may be considered useful as a routine biochemical technique for measurement of serum CRP concentration in the dog.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Veterinary research communications 22 (1998), S. 77-85 
    ISSN: 1573-7446
    Schlagwort(e): C-reactive protein ; circadian rhythm ; dog ; ELISA ; physiological variation ; serum
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract This study was undertaken to investigate whether the level of C-reactive protein (CRP) in the serum of dogs undergoes physiological variation, using 10 normal Beagle dogs (5 males and 5 females), 1–2 years old, maintained in a healthy condition in a controlled environment. The CRP concentration in the sera collected seven times each day at intervals of approximately 3 h ranged from 0.8 to 16.4 µg/ml (mean 5.06±3.60) in one experiment and from 0.8 to 14.0 µg/ml (mean 4.50±2.80) in a second experiment. On examining the 24-h variations in the concentration of CRP in serum, neither consistent changes nor a definite pattern of circadian rhythm was detected. During 28 days observation, only very slight changes, which seemed attributable to analytical errors, were seen in any of the dogs, except one. The concentration of CRP in the serum during the 28 days ranged from 0.8 to 22.6 µg/ml (mean 3.65±1.40). The concentrations underwent no significant variations in individual dogs, but significant differences were found between the dogs (p〈0.01).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...