Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of clinical monitoring and computing 10 (1993), S. 101-107 
    ISSN: 1573-2614
    Keywords: noninvasive sensor ; respiratory rate ; patient monitoring ; acoustic air flow sensor ; patient recovery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science , Medicine
    Notes: Abstract The need for continous, noninvasive, and reliable respiratory rate monitoring during recovery from general anesthesia has long been recognized. Alternative principles can be grouped into those detecting the respiratory effort, and those detecting the actual result, i.e. the respiratory gas flow. The second category is of greatest interest for patient monitoring. In this paper, we report the development and initial clinical experience with a new acoustic air-flow sensor. By differential, multipoint detection of the air-flow in the mouth and nose region, the sensor can easily discriminate against different kinds of interference, including motion arterfacts. The sensor is nonexpensive, rugged, simple to apply, and inherently safe. An instrument with continous display of respiratory rate, and an audiovisual apnea alarm has been designed and built. The complete system has been tested on patients during recovery after general anesthesia. In 16 patients, the respiratory rate displayed by the instrument has been correlated against that visually observed. A good correlation was obtained. Minor discrepancies can be explained from the fact that visual observation corresponds to the respiratory effort, whereas the sensor detects the actual air flow. In 12 patients, 24 hour simultaneous recordings were made of respiratory rate with the new sensor, with simultaneous recording of the oxygen saturation and the heart rate with a pulse oximeter. It was found that the new sensor reliabley recorded respiratory depression and apnea. Such events may in some patients be as frequent as one incident per hour. One case of ‘Ondine's curse’ provided clear evidence that pulse oximetry has a low sensitivity to respiratory disorders.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...