Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (2)
  • 1950-1954
  • radiation treatment  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Pharmaceutical research 14 (1997), S. 1192-1196 
    ISSN: 1573-904X
    Schlagwort(e): dopamine ; norepinephrine ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on dopamine and norepineprine by ESR spectroscopy. Results and Discussion. Equations to describe the evolution of the ESR curves versus doses and time of storage are presented. Linear regression is, for dopamine hydrochloride, applicable for doses ranging from 10 to 25 kGy. Since the radiation dose selected must always be based upon the bioburden of the products and the degree of sterility required, doses in the range 10−25 kGy could be investigated and linear regression would appear to be the least expensive route to follow and gives good results. The comportment of noradrenaline bitartrate is more complex and the use of linear regression would appear more hazardous especially for low doses. For doses higher than 25 kGy, a more general equation is required. Power function using only 2 parameters could give good results but must be validated. Decay kinetics for radicals versus storage were considered. Non-homogenous kinetics with time dependent rate constant and bi-exponential function appeared valid to reproduce the decay of radicals for, respectively, dopamine and norepinephrine. Conclusions. It is worth noting that, at present, ESR is the only technique which proved to be suitable for identification and quantification purposes in irradiated pharmaceuticals. Moreover, other features such as sensitivity, precision, ease and non-destructive readout make ESR superior to other proposed analytical techniques.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Pharmaceutical research 14 (1997), S. 810-814 
    ISSN: 1573-904X
    Schlagwort(e): formoterol ; radiation treatment ; ESR spectroscopy ; dosimetry ; storage ; HPLC ; degradation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Purpose. Radiation sterilization is becoming increasingly popular for the sterilization of many pharmaceutical products. We have investigated the gamma radiation induced effects on formoterol fumarate by HPLC and ESR spectroscopy. Results and Discussion. Numerical simulation of the evolution of the ESR signal versus dose was performed using linear regression, quadratic fit and power function. The shape of the dosimetric curve is linear in the range 5−30 kGy. Owing to the weak number of free radicals generated during the irradiation, the accuracy of measurements is low. For a dose of 25 kGy, discriminating irradiated from unirradiated samples is possible if the storage period is less than 250 days. The comparison between chromatographic profiles of irradiated and unirradiated samples showed minor differences. Conclusions. From our preliminary results, radiosterilization of formoterol fumarate may be technically feasible. Estimation of the irradiation dose by ESR may be possible but, due to the weak number of free radicals generated during the irradiation, the accuracy of measurements appeared low.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...