Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Biochemistry and Biotechnology  (2)
  • solid phase extraction  (2)
  • 1
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 303-315 
    ISSN: 1040-7685
    Schlagwort(e): capillary GC ; solid phase extraction ; membrane disks ; water samples ; automation ; nitrogen-phosphorus detection ; mass selective detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: An automated procedure for the analysis of aqueous samples by membrane disk extraction coupled on-line to capillary gas chromatography (GC) is presented. Organophosphorus pesticides are preconcentrated from aqueous samples on three 0.5 mm thick, 4.0 mm diameter XAD-2 membrane extraction disks which are mounted in a polymer holder for use in a PROSPEKT sample processor. The layers are dried by a stream of nitrogen (30 min at ambient temperature). Desorption of the analytes is carried out with ethyl acetate which is directly introduced into a retention gap under partially concurrent solvent evaporation conditions, using an early solvent vapor exit. The method is a fully software-controlled automated system, and includes sample preparation, sample transfer and GC analysis. The final analysis is carried out by GC with nitrogen-phosphorus (NPD) or mass-selective detection. The technique is applied to the determination of a series of organophosphorus pesticides in tap water and water from European rivers. With a sample volume of only 2.5 mL, the detection limits achieved with the NPD were 20-50 ng L-1 in tap water and 20-100 ng L-1 in river water.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1040-7685
    Schlagwort(e): solid phase extraction ; thermal desorption ; on-line ; aqueous samples ; gas chromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A module for combined solid-phase extraction and thermal desorption (SPETD) was incorporated into a system for automated GC analysis. Solid-phase extraction of analytes from water could be carried out after injection of an aqueous sample of 100 μL either by a loop using the carrier gas for sample introduction or manually with a syringe. After drying of the stationary phase by the carrier gas at a high flow rate, thermal desorption could be carried out at temperatures up to 300-350°C. Suitable packing materials for the liner in the SPETD module, i.e., materials which efficiently trap the organic compounds from an aqueous solution and are sufficiently thermostable, include Tenax and carbon-based phases, as well as a silylated alkylmodified silica. With the latter, however, the problem of efficient drying after sorption still must be solved. Each phase has its own application range which, from among the analytes which are trapped during sorption, is determined at the volatile end by losses occurring during drying by helium purging, and at the nonvolatile end by losses due to incomplete release during thermal desorption. From this study (using n-alkanes, chlorobenzenes, and chlorophenols as test solutes), it appears that the Tenax phases, Tenax-TA and Tenax-GR, have the widest application range; essentially quantitative recoveries were obtained for C10 through C26 n-alkanes. The carbon-based phases appear to be useful for relatively volatile compounds, i.e., up to C19 n-alkanes. Each phase gave good recoveries for two test mixtures containing chlorobenzenes and chlorophenols dissolved in 100 μL of water at the 10 ppb level.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 4 (1989), S. 484-499 
    ISSN: 0884-3996
    Schlagwort(e): Luminescence ; chromatography ; detection ; quantitative analysis ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: An overview is presented of the physicochemical basis of luminescence, and its application to the detection of chemicals (drugs, biomedically important compounds, environmentally active substances) in liquid chromatographic systems.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0173-0835
    Schlagwort(e): Capillary electrophoresis ; Dialysis ; Sample pretreatment ; Serum ; Sulfonamides ; Urine ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A fully automated dialysis solid-phase extraction (SPE) sample preparation procedure is coupled on-line to capillary electrophoresis (CE) for the first time. The system is used to determine sulfonamides in serum and urine. The dialysis unit serves to remove proteins and particulate matter. Reconcentration of the analytes is performed with a small SPE column while (in)organic salts and other interferences are removed simultaneously. Finally, the analytes are desorbed and injected, via a homemade interface, into the CE system. Limits of detection (LOD) of 0.05-0.1 and 0.05-0.3 μg/mL are obtained in urine and serum, respectively. The within-day and between-day precisions are in the range of 2-6% and 3-8%, respectively, for a concentration of five times the LOD. The dialysis SPE-CE system was used over a period of six months for the analysis of over 500 serum and urine samples without problems such as clogging of the CE capillary or SPE column.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...