    ISSN: 1573-2630
    Keywords: cornea ; fluorophotometry of the anterior segment ; glaucoma surgery ; tissue plasminogen activator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract After glaucoma filtering surgery subconjunctival injection of human recombinant tissue plasminogen activator may promote the function of glaucoma filter bleb and increase outflow facility. It can also increase postoperativae complications, such as corneal damage. The aim of our research was to determine corneal endothelial permeability (Pac) in subjects with glaucoma filter bleb protected by a plasminogen activator (Actilyse, Boehringer) when haemorrhagic clots obstructing a glaucoma filtering site had occurred. Two weeks, three months and six months after goniotrephining with scleral cover, in groups with and without subconjunctival injection of 25 mg human tissue plasminogen activator, Pac was calculated. In both groups, no significant differences in the level of Pac measured by fluorophotometry were found.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International ophthalmology 16 (1992), S. 387-390 
    ISSN: 1573-2630
    Keywords: glaucoma ; filtering surgery ; tissue plasminogen activator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Since 1987 we have performed, with good results, glaucoma filtering surgery in which the limbo-scleral fistula was closed by an autogenic full blood clot (sclerectomy under a clot). In 8 patients with advanced stages of glaucoma simplex, 1–3 days after sclerectomy under a clot with rise IOP, 25μg of tissue plasminogen activator (tPA) was injected subconjunctivally. Two weeks after surgery normalization of IOP below 15 mmHg and normal outflow facility in all tPA treated eyes were obtained. No increase in early postoperative complications, such as hemorrhage or corneal haze, was attributable to tPA use. In early period after sclerectomy under a clot, when blockage of outflow appears, the use of tPA can cause the re-creation of filtering tract.