Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: This report describes the case of an 8-year-old boy with hypertrophic cardiomyopathy (HCM) who underwent ICD implantation for recurrent syncope. To avoid vascular complications and to minimize the surgical approach in this small child, a nonthoracotomy ICD system was chosen using a single subcutaneous array lead with only one finger, an abdominally placed active can, and epicardial dual chamber pacing and sensing electrodes. During an 8-month follow-up, DFT was confirmed and there were no ventricular tachycardia or complications. It appears to be a safe device for the prevention of sudden cardiac death in infants and small children. (PACE 2004; 27:117–119)
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1460-9592
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Therapy of hypoplastic left heart syndrome (HLHS) consists of the staged Norwood procedure or cardiac transplantation. Stenting the ductus arteriosus and subsequent banding of the pulmonary arteries allows the combination of neoaortic reconstruction with the establishment of a bidirectional cavopulmonary connection (combined stage 1 and 2 procedure) in a later session. We report the anaesthetic management in eight infants ranging from 107 to 195 days undergoing a combined stage 1 and 2 procedure. Nonselective pulmonary vasodilators and nitric oxide were needed in all cases to improve oxygen saturation in the postbypass period. Phosphodiesterase inhibitors and epinephrine were required in all patients for inotropic support during and after weaning off cardiopulmonary bypass. The procedure was successful in seven patients. One patient died intraoperatively because of right heart failure. The physiological changes of this new surgical strategy for palliation of HLHS offers a challenge for the anaesthetist primarily in the early postbypass period.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    350 Main Street , Malden , MA 02148-5020 , USA , and P.O. Box 1354, Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of interventional cardiology 18 (2005), S. 0 
    ISSN: 1540-8183
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Nonsurgical closure of congenital and acquired ventricular septal defects (VSD) has become increasingly acceptable with the availability of various occlusion systems that allow percutaneous treatment of muscular and membranous defects. This study describes a series of 12 patients (0.2–74-years-old) who underwent defect closure with six different occlusion systems. Device selection according to anatomy and outcome is highlighted. Seven VSDs were located in the membranous part of the septum, five in the mid-muscular septum. Complex heart lesions were present in five postmyocardial infarction VSD in one and residual postsurgical defects in three patients. The size of the VSD ranged from 2.6 to 10 mm. The applied devices were: Amplatzer muscular VSD occluder (n = 4), Amplatzer septal occluder (n = 2), Amplatzer duct occluder (n = 1), Amplatzer membranous VSD occluder (n = 2), Nit-Occlud coil (n = 2), and Cook PDA coil (n = 1). The devices were implanted successfully in nine patients. There was complete VSD closure in eight patients within the first 24 hours. In one patient, a trivial residual shunt disappeared at 6 months follow-up. Because of device instability, two occluders were removed during catheterization. In two other cases, tricuspid valve tissue was entrapped in the occluder and had to be removed surgically, one of them during the consecutive Rastelli operation. Neither significant arrhythmia, nor thromboembolism or hemolysis occurred in out patients during follow-up. Transcatheter closure of VSD is an attractive alternative to surgery. In complex congenital heart disease, surgical-interventional hybrid therapy may improve morbidity and total outcome. The recently developed Amplatzer VSD devices allow closure of muscular and membranous VSDs. Implantation and short-term follow-up are superior to the formerly used devices. Long-term effects have to be evaluated in further studies.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...