Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 5422-5427 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Details of experiments aimed at achieving low ionization state selectivity in molybdenum are presented. Targets are excited with a 10 J CO2 laser and the resultant vacuum ultraviolet spectrum (300–700 A(ring)) has been studied. Combinations of focal spot size, target depth, and target geometries are compared. Simple attenuation of energy is shown not to vary ionization stage composition significantly. Experiments conducted with grazing incidence targets result only in a hot plasma. Modular targets with cooling cylinders of various radii demonstrated good selectivity of the ionization states, but with low absolute signals. Finally, results from combinations of focal spot adjustment and radiative cooling illustrate increased control over desired plasma temperature and density for spectroscopic studies of molybdenum.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 1601-1615 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A high-resolution, time-resolving soft x-ray multichannel spectrometer (SOXMOS) that permits the simultaneous measurement of emission in two different spectral ranges has been developed and tested extensively for tokamak plasma diagnostics. The basic instrument is a high-resolution, interferometrically adjusted, extreme grazing incidence Schwob–Fraenkel duochromator. The instrument is equipped with two multichannel detectors that are adjusted interferometrically and scan along the Rowland circle. Each consists of an MgF2 coated, funneled microchannel plate, associated with a phosphor screen image intensifier that is coupled to a 1024-element photodiode array by a flexible fiber-optic conduit. The total wavelength coverage of the instrument is 5–340 A(ring) with a measured resolution (FWHM) of about 0.2 A(ring) when equipped with a 600-g/mm grating, and 5–85 A(ring) with a resolution of about 0.06 A(ring) using a 2400-g/mm grating. The simultaneous spectral coverage of each detector varies from 15 A(ring) at the short wavelength limit to 70 A(ring) at the long wavelength limit with the lower dispersion grating. The minimum readout time for a full spectral portion is 16 ms, but several individual lines can be measured with 1-ms time resolution by selected pixel readout. Higher time resolution can be achieved by replacing one multichannel detector with a single channel electron multiplier detector. Examples of data from the PLT and TFTR tokamaks are presented to illustrate the instrument's versatility, high spectral resolution, and high signal-to-noise ratio even in the 10-A(ring) region.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 849-851 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Soft-x-ray (5–300 A(ring)) spectra of intrinsic impurities have been recorded with a high-resolution multichannel XUV spectrometer (SOXMOS). Measurements of line intensity ratios as a function of time are applied to the determination of the impurity contribution to the energy balance. Results from TFTR Ohmic heated plasmas, including radiation due to carbon, oxygen, iron, nickel, chromium, titanium, and zirconium, are presented. The spatial ion distribution will be directly observed by a radial scanning spectrometer (FLOPSY). This instrument, under construction, will cover the spectral range from 1500 to 7000 A(ring) and use mirrors and lenses for fast scanning. The spatial ion distribution, deduced from forbidden and allowed lines, will be compared to both theoretical models based on impurity concentrations and transport coefficients, as well as experimental data from bolometer measurements.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Space science reviews 13 (1972), S. 589-591 
    ISSN: 1572-9672
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...