Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Schlagwort(e): Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0935-6304
    Schlagwort(e): Coupled LC-GC ; Retention gap ; LC trace enrichment ; Aqueous samples ; Organic pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m retention gap coupled to the capillary GC column served as the recipient of a relatively large sample volume (ca. 100 μl) introduced into the GC. Partially concurrent solvent evaporation during sample introduction allowed a large sample capacity. Recoveries of more than 95% were observed for the majority of the compounds studied. Using 1.0 ml aqueous samples, detection limits of less than 1 ppt were found. The applicability of the developed method was demonstrated for a river water sample.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...