Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    International archives of occupational and environmental health 66 (1994), S. 97-102 
    ISSN: 1432-1246
    Schlagwort(e): Human skin ; Vibratory sensation Vibration exposure ; Threshold shift ; Acute effect
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A new, self-recording, vibratory sensation meter measures temporary threshold shifts of vibratory sensation (TTSv) on a finger tip. After exposure to hand-transmitted vibration with exposure frequencies 63 Hz, 200 Hz and 500 Hz, and levels of acceleration 1 g, 2 g, 4 g and 8 g, fingertip measurements were obtained. Temporary threshold shift immediately after the vibratory exposure (TTSVv,0) was estimated for each exposure from the regression analysis by approximation of an exponential function. Time constant (tc) was also estimated at the same time by the analysis. The coefficients of determination were large. Thus, the fit of the exponential function is very good for each exposure. The tc corresponds to the recovering velocity of the temporary shift and implies the half-life period of TTSv. These parameters enable us to examine more generally the relationships of TTSv to the characteristics of exposure vibration, subject and other conditions. On this basis, the estimated TTSv,0 and tc were used to examine the dependency of TTSv on the characteristics of the exposure vibration and the subject. The most effective frequency under the level of 4 g is thought to be between 200 Hz and 500 Hz. TTSv,0 of each subject proportionally increased with power of acceleration. The coefficient of determination on regression analysis was large. This result enables us to estimate TTSv,0 at an arbitrary level of acceleration by use of a regression equation derived from experimental data.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    International archives of occupational and environmental health 63 (1992), S. 531-535 
    ISSN: 1432-1246
    Schlagwort(e): Human skin ; Temperature sensation ; Vibration exposure
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The temporary threshold shift of temperature sensation due to vibration exposure was studied to clarify the significance of frequency and acceleration on it. The discrete frequencies of the vibrations tested were 32, 63, 125, 250 and 500 Hz, and the accelerations were at the level of 2, 4, 8 and 16 g. The threshold shift of warm sensation (TTSw) was markedly, but that of cool sensation was small and not significantly different from the control value. TTSw increased with a rise in the level of acceleration and was largest at 125 Hz among the frequencies examined. The most effective frequency among the vibrations tested for warm sensation was inferred to be lower than that for vibratory sensation. After exposure, TTSw or the increment of the neutral zone decayed exponentially but bounced slightly in the later period. These patterns of TTSw are similar to those of the vibration-induced TTS of vibratory sensation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...