Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 21 (1996), S. 517-521 
    ISSN: 1432-0509
    Keywords: Key words: Pancreas, anatomy—Pancreas, computed tomography—Computed tomography, helical technology.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Background: To assess the frequency of visualization of pancreatic arteries in the arterial phase of helical computed tomography (CT). Methods: The visibility of pancreatic and peripancreatic arteries in helical CT images was evaluated in 20 consecutive patients who had no evidence of pancreatic disease. CT examinations were performed by using a continuously rotating CT scanner and intravenous injection of contrast media. The scans were taken 35 s after the start of injection and with a table speed of 3 mm/s. Images were reconstructed in 3-mm section increments. Results: Frequently visualized arteries were the gastroduodenal, anterior and posterior superior pancreaticoduodenal, and right gastroepiploic arteries. Infrequently visualized arteries were the dorsal pancreatic, pancreatica magna, caudal pancreatic, transverse pancreatic, and common, anterior, and posterior inferior pancreaticoduodenal arteries. Conclusion: Helical CT enabled us to recognize small pancreatic arteries, and the evaluation of these arteries should be considered in the staging of pancreatic carcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1432-0509
    Keywords: Key words: Computed tomography, technology—Pancreas, CT—Pancreatic adenocarcinoma, CT.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Background: Spiral computed tomography (CT) allows the pancreas to be imaged during peak contrast levels owing to the capability of fast data acquisition. The objective of this study was to evaluate the relative value of the arterial and late phases of spiral CT for detecting pancreatic adenocarcinomas. Methods: Twenty-two patients with pathologically proved pancreatic adenocarcinomas underwent two-phase spiral CT. The CT scans were performed with 5 mm collimation and 5 mm/s table speed. Images during the arterial and late phases were obtained at 30- and 180-second delays, respectively. The images of the arterial phase were compared with those of the late phase in terms of tumor conspicuity from surrounding pancreatic parenchyma and tumor detectability by means of a 3-point grading system: 1 (poor), 2 (fair), and 3 (good). Results: In terms of tumor conspicuity from surrounding pancreatic parenchyma, 16 lesions (73%) were good, 5 lesions (23%) were fair, and 1 lesion (4%) was poor during the arterial phase, whereas 6 lesions (27%) were good, 9 lesions (41%) were fair, and 7 lesions (32%) were poor during the late phase (p= 0.0007). The arterial phase was superior to the late phase in 16 patients (73%) and equal in 6 patients (27%). For tumor detectability, 18 lesions (82%) were good, 3 lesions (14%) were fair, and 1 lesion (4%) was poor during the arterial phase, whereas 10 lesions (45%) were good, 7 lesions (32%) were fair, and 5 lesions (23%) were poor during the late phase (p= 0.0033). For detectability, the arterial phase was superior to the late phase in 14 patients (64%) and equal in 8 patients (36%). Conclusion: The arterial phase of spiral CT is superior to the late phase, which is equivalent to conventional CT for detecting pancreatic adenocarcinoma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Abdominal imaging 24 (1999), S. 250-257 
    ISSN: 1432-0509
    Keywords: Key words: Liver—Neoplasms—US—CT—MR.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: To verify characteristic features of hepatic dysplastic nodules at different imaging modalities. Methods: Twenty-eight patients with 37 dysplastic nodules of the liver (0.8–3.0 cm) underwent sonography (28 patients), computed tomography (CT; 24 patients), magnetic resonance (MR; 11 patients), and angiography (12 patients). Each nodule was analyzed for echogenicity, attenuation, signal intensity, and vascularity. Results: Echogenicity of nodules was high in 16 (43%), homogeneous in two (6%), and low in 19 (51%) of 37 nodules. Attenuation of nodules was high in one (7%), homogeneous in four (26%), and low in 10 (67%) of 15 nodules on the arterial-phase CT images; homogeneous in five (33%) and low in 10 (67%) of 15 nodules on the portal-phase CT images; and high in four (17%), homogeneous in six (26%), and low in 13 (57%) of 23 nodules on the delayed-phase CT images. Signal intensity of nodules was high in 15 (94%) and homogeneous in one (6%) of 16 nodules on T1-weighted MR images and was homogeneous in seven (44%) and low in nine (56%) of 16 nodules on T2-weighted MR images. Vascularity of nodules was avascular in 14 (88%) and slightly vascular in two (12%) of 16 nodules. Conclusions: Hepatic dysplastic nodules show diverse imaging characteristics with different imaging techniques; however, common imaging findings of hepatic dysplastic nodules are low echo, low attenuation, and high, low, or homogeneous intensity on T1- and T2-weighted MR, and avascularity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1432-0509
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1432-1920
    Keywords: Key words Computed tomography ; head and neck ; Contrast medium ; dose ; Comparative study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Adequate contrast enhancement of major neck vessels is more important than that of a tumour itself in CT of most head and neck tumours because of differentiation from neck node metastases. Our purpose was to re-evaluate the dosage of contrast medium for adequate vascular enhancement in CT of the head and neck. In a blind prospective fashion, 60 patients with a variety of head and neck lesions were randomised into three equal groups receiving 0.75, 1.0, or 1.25 ml/kg of meglumine ioglycate, 300 mg/ml. Contrast medium was administered by injector at 2 ml/s. The scan time and interscan delay were each 1 s, and total scan time 50–180 s. The scan was started immediately after administration of two-thirds of the contrast medium. The degree of vascular enhancement was assessed visually and quantitatively. We visually scored the degree of vascular enhancement as excellent (4 points), good (3), fair (2) or poor (1). For quantitative study, after measuring the CT numbers of the common or internal carotid artery (CA), internal jugular vein (IJV) and adjacent muscle at three levels, were calculated mean vessel/muscle contrast ratios. The degree of enhancement of the CA and IJV tended to increase with dose of the contrast media, but no examination was rated as showing poor enhancement in any group. The mean visual assessment scores for 0.75, 1.0, and 1.25 ml/kg were 2.7, 2.9 and 3.1, respectively; the mean ICA/muscle contrast ratios were 1.58, 1.55 and 1.63, and those of IJV/muscle 1.65, 1.59 and 1.59. There was no significant difference between visual and quantitative assessment in any group. The results suggest that 0.75 ml/kg of contrast medium appears sufficient for vascular opacification for head and neck lesions when the CT scan can be completed in about 120 s.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...