Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 67-71 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A technique has been developed to determine the absolute single particle counting efficiency of a channel electron multiplier (CEM) for positively charged ions at keV energies. The calibration technique is applicable to positive ion detectors in general. Ion beam currents of C2+ were created by charge transfer of C3+ on H2 in the thin target regime. By adjusting the H2 pressure in the beam scattering chamber from 10−10 to 10−6 Torr, C2+ currents could be created either low enough to be detected by the CEM in the particle counting mode or high enough to be measured as a current using the CEM as a Faraday cup. The CEM counting efficiency was determined by comparing the C2+ count rate to the C2+ current, scaling by the change in H2 pressure, and also scaling by the incident C3+ current for each C2+ measurement. This method, which effectively uses the charge transfer cross section as a "transfer standard,'' allows the CEM counting efficiency to be determined in situ and to be monitored accurately over extended periods of time. The calibration requires that only the relative, not the absolute, pressure change be known. The technique does not require the value of the charge transfer cross section to be known. The accuracy of the calibration technique for the present results was 10% at a confidence level considered to be equivalent to a statistical 90% confidence level. For the present work, the peak counting efficiency of a Galileo 4039 CEM for 32.5 keV C2+ ions was determined to be 96%. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of the American Chemical Society 81 (1959), S. 3784-3786 
    ISSN: 1520-5126
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2254-2265 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: An inclined beams apparatus for the measurement of absolute cross sections for dielectronic recombination between free electrons and singly or multiply charged ions is described. The collision products, a photon and a lower-charge-state ion, are detected in delayed coincidence. Measurements of dielectronic recombination in C3+ are described to illustrate the use of the apparatus and techniques. Verification of the calibrations and operation of the apparatus is demonstrated through measurements of charge transfer and electron impact excitation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A novel method is described that combines the production of ions by laser ablation with an ion-trap technique for the measurement of thermal-energy charge-transfer rates of multiply charged ions and neutrals. The charge-transfer rate is determined by measuring the rate of loss of stored ions from the trap. Verification of the calibration of the apparatus is demonstrated through investigation of charge transfer of N2 and N2+, which has been studied by another group. We also have made the first measurement on the thermal-energy charge-transfer coefficient of Ar and W2+. The rate coefficient is 0.99(0.22)×10−11 cm3 s−1.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 383-392 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: An ion beam apparatus for the absolute measurement of collision cross sections in singly and multiply charged ions is described. An inclined electron and ion beams arrangement is used. Emitted photons from the decay of collision produced excited states are collected by a mirror and imaged onto a photomultiplier. Absolute measurements of the electron impact excitation of the 2s–2p transition in C3+ were used to demonstrate the reliability of the apparatus.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 177-184 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: An apparatus is described for studying the photodissociation of neutral free radicals and positive molecular ions with a fast beam technique. Particular attention is given to studies of diatomics whose constituent atoms have very different masses and to photodissociation of polyatomic systems. Novel features of this design include fast neutral beam generation by photodetachment of negative ions, beam energies sufficiently high to detect neutral products, and a beam filter for reducing noise from background processes. A position-sensitive detector provides the data required to determine separation energies and angular distributions for dissociation studies where only one fragment is detectable.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Ground water monitoring & remediation 16 (1996), S. 0 
    ISSN: 1745-6592
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Energietechnik , Geologie und Paläontologie
    Notizen: Hydrologic investigations typically involve the collection of water level measurements at discrete points in space and time. The high cost of commercial electronic recorders can be a burden. We have developed an inexpensive (∼$200) electronic water level recorder consisting of a Motorola microcontroller, a clock, memory, pressure transducers, and associated circuitry. The instrument is powered by a 6-V battery. These devices, each capable of monitoring up to eight channels of analog input, are presently providing continuous monitoring of nested piezometers, tide gauges, and rain gauges in hydrologic studies at the Savannah River site and the North Inlet (South Carolina) Long-Term Ecological Research (LTER) site. The instruments can be custom tailored to record water levels at any specified time interval, or whenever the water level changes by a specified amount, and can store up to 32,000 water level observations. These instruments have been used to conduct slug tests and can be configured to monitor observation wells for pumping tests. Simplicity of construction and availability of components offer hydrologists an inexpensive but reliable method of water level recording. Several examples of the use of this instrumentation in diverse hydrologic settings are described.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Industrial and engineering chemistry 3 (1964), S. 28-33 
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Industrial & engineering chemistry 56 (1964), S. 83-83 
    ISSN: 1520-5045
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Journal of agricultural and food chemistry 1 (1953), S. 521-522 
    ISSN: 1520-5118
    Quelle: ACS Legacy Archives
    Thema: Land- und Forstwirtschaft, Gartenbau, Fischereiwirtschaft, Hauswirtschaft , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...